Main components |
Technique parameter |
|
IMD X-ray tube |
Model:YSX-C35D |
Model:YSX-C50D |
|
Power:3.5kW |
Power:5.0kW |
|
Double focus fixed anode focus:1.5mm / 0.6mm |
Double focus rotational anode focus: 0.3mm / 0.6mm |
|
Anode Heat Capacity:40kHu X-ray tube sleeve heat capacity:667kHu |
Anode Heat Capacity:200kHu X-ray tube sleeve heat capacity:800kHu |
|
High Voltage X-ray Generator |
Working frequency:40kHz |
|
Image intensifier |
9"(including 3 fields of view 4.5"/ 6"/9") |
|
Tube voltage |
Fluoroscopy Radiograph:40kV-110kV |
Fluoroscopy Radiograph:40kV-120kV |
|
Tube current |
Fluoroscopy: 0.5-4mA Enhanced Automatic Fluoroscopy: 1mA-8mA Pulse Fluoroscopy :2pps;8mA |
|
mAs |
1mA.s-250mA.S |
|
Fluoroscopy mode |
Manual Fluoroscopy; Semi-Automatic Fluoroscopy;Automatic Fluoroscopy; Enhanced Automatic Fluoroscopy; Pulse Fluoroscopy |
|
Intelligent exposure control |
No matter the object is in the center or on the fringing field of the image intensifier, the images are the same. The exposure dose is reduced. |
|
Iris beam limiting device |
when not exposure, keep in the state of Iris Beam limiting preview ,when exposure,keep blanking cycle track |
|
|
General radiography |
40kV-120kV;1.0mA.s-250mA.s |
step length 1 kV;1.0mA.s |
|
Digital radiography (digital spot film) |
40kV-120kV;Max 16mA |
Common screen film radiography is eliminated. Digital radiography can get better images |
|
C-arm machinery index |
C-arm stander(with perfect C arm balance system) of ultra-quiet motor-driven up and down, easy and handy to operate. The machine can maintain balance with up and down of the C arm. |
|
Distance between focus and window>900mm, arc depth>650mm, horizontal moving range :200mm vertical moving range:400mm |
|
Tilt angle :±12.5° rotation :±180°corner:125°(-35°-- +90°) |
|
Laser Orientation |
Laser positioning function can help to position precisely and reduce exposure times in the operation, reduce unnecessary radiation. |
|
Radiography mode |
|
Image intensifier & Real-time digital image(1.3 million pixel) processing system |
|
(CCD)Digital video camera |
million pixels high-definition, high-speed CCD camera, a 1024 × 1024 matrix, 30 frames per second image acquisition, through real-time adjustment of window width, window level, noise reduction, sharpening and Gain adjustment to ensure high-quality and high-resolution images. |
|
Image resolution index |
Grey level:10 Resolution:22 lp/cm |
|
Camera virtual rotation design |
No X-ray needed, also called digital image rotation,display the right angle when exposure, superior to camera mechanical rotation |
|
Image processing system |
1.Real time edge enhancement(sharpening) |
Image sharpening is also called edge enhancement, that is, to make blurry edge of the image clearer |
|
2.Real time adjustment of the window width and window level |
Obtain images by real-time adjustment of window width,window level, displaying images with different brightness. |
|
3.Real time(static)multiform noise reduction |
Noise reduction, and improve image clarity |
|
4.Real tim GAIN adjustment |
Can amplify image signal, reduce x-ray dose, suitable for patient with super large size. |
|
5.Real tim dynamic brightness compensation and R calibration functions |
Through dynamic logarithmic transformation,linear reduction the system signals and r calibration technology, dark parts of the image can be enhanced and clear rich-layer images can be obtained |
|
6.Image conversing ,up-down and right-left rotating,and frame freezing |
|
7.Patient information management ,Clinic report and print |
|
8.The Image can be storage as JPG and DICOM 3.0 format, can be linked to hard-disk ,USB and DVD and printer,meet the need of sharing the network information ,communication and storage in hospital |
|
Display |
Display2 17' TFT-LCD display |
|
Printer |
Printer Laser / jet Printer |
|
Standard configuration |
1.Combined tube(5.0kW)IMD |
1 set; |
|
2.Image intensifier (9 inch 3 fields of view) |
1 set |
|
3.C-arm stander (with full C-arm balance system) |
1 set; |
|
4.Exported grid |
1 set |
|
5.Laser positioning |
1 set; |
|
6.1.3million pixel 1024×1280×10bit camera |
1 set; |
|
7.Electric adjustable beam limiting device |
1 set |
|
8.17 inch LCD high resolution screen |
2 sets |
|
9.Real-time digital imageprocession system (station) |
1 set; |
|
10.Printer |
1 set |
|