• Hospital Medical 5kw Touch Screen High Frequency Mobile X Ray Machine
  • Hospital Medical 5kw Touch Screen High Frequency Mobile X Ray Machine
  • Hospital Medical 5kw Touch Screen High Frequency Mobile X Ray Machine
  • Hospital Medical 5kw Touch Screen High Frequency Mobile X Ray Machine
  • Hospital Medical 5kw Touch Screen High Frequency Mobile X Ray Machine
  • Hospital Medical 5kw Touch Screen High Frequency Mobile X Ray Machine

Hospital Medical 5kw Touch Screen High Frequency Mobile X Ray Machine

Classification: Imaging Diagnostic Equipment
Type: X Ray Equipment
Certification: ISO13485
Group: All
Power Frequency: 30kHz
Input Voltage: 220±10%
Customization:
Diamond Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
YSX70GM/YSX100GM
Frequency
50Hz±1Hz
Max. X Ray Tube Voltage
110kv
Exposure Size
≥350mm*350mm(Sid=65cm)
Adjustable Range
380±10% At220V Being Adjustable
Gross Weight
202kg
Mas Range
1-125mas/200mas
Resistance
≤0.5Ω
Filament Frequency
20kHz
Transport Package
Standard Export Wooden Case
Trademark
ysenmed
Origin
Guangzhou
Production Capacity
150 Sets/Month for Portable X-ray

Product Description

Hospital medical 3.5kW/5.0kW high frequency generator X-ray tube touch screen mobile x ray machine
Model: YSX70GM-B/YSX100GM
Hospital Medical 5kw Touch Screen High Frequency Mobile X Ray Machine

Technique Specification

 

Model

YSX70GM-B

YSX100GM

Power                                                    

Input Voltage

220V±10%

Input Power

5.5kW

7.5kW

Mains Frequency

50Hz±1Hz

Source Resistance

≤0.5Ω

Main Technical Parameters

Power Modules

30kHz

 

Filament Frequency

20kHz

 

Focus

1.5mm

 

Max. Generator Output

3.5kW;

5kW

Max. X-Ray Tube Voltage

110KV

120KV

kV Range

40~120kV

mAs Range

1~125mAs

1~200mAs

Main Parameters Of Mechanical Parts

X Ray Tube Vertical Motion Range

≥500~1750mm

X Ray Source Components Around The Cross Arm Vertical Rotation:≥±90°

Exposure Size

≥350mm*350mm(SID=65cm)

Machine Main Function

Fault Detection Error Prompt Functions

ARP Human Anatomy Program Function

Parameter Calibration Function

 

Combined X-Ray Tube Assembly

1,Adopt high frequency high voltage generator and combined X-ray tube assembly;

2,kV closed-loop control, stable output, good repeatability, quick response and high accuracy;

3,mAs digital closed-loop control technology and 32-bit microprocessor real-time control, which ensure the accuracy and repeatability of dosage;

 

Inverter

1,Equipped with the functions of high voltage and over & under voltage protection, tube current over-current protection, output overload protection and fault prompt;

2,Perfect heat capacity protection function to protect X-ray tube target surface;

 

Corrugated Pipe

Full consideration of hospital disinfection and cleaning, adopt high quality corrugated pipe, prolonging the service life of the equipment

 

Switch

Using high quality switch, safe and reliable, stable quality

 

Wheel

The machine moves very flexible, lightweight, even in a small space can also smoothly, quickly through



Hospital Medical 5kw Touch Screen High Frequency Mobile X Ray Machine


Hospital Medical 5kw Touch Screen High Frequency Mobile X Ray Machine

Hospital Medical 5kw Touch Screen High Frequency Mobile X Ray Machine

Hospital Medical 5kw Touch Screen High Frequency Mobile X Ray Machine

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now