Ysf8-S Medical Multi-Parameter Portable Patient Monitor

FOB Price: Get Latest Price
Min. Order: 1 Set
Production Capacity: 5, 000sets /Year
Transport Package: Wooden Case
Payment Terms: L/C, T/T, Money Gram, Western Union

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: YSF8-s
  • Type: Patient/Fetal/Maternal Monitor
  • Group: All
  • Weight: Tandard Configuration: 4.4 Kg
  • Display: 12.1′color TFT LCD Screen
  • Operation Mode: Diagnostic, Monitor, Surgery
  • Trademark: YSENMED
  • Origin: China
  • Classification: Physiological Functions of Diagnosis and Monitoring Equipment
  • Certification: ISO13485
  • Dimension: 375mm(W)*330mm(H)*180mm(D)
  • Power: AC 90-300V, 50/60Hz, 60W
  • Measurement Range: Dult: 0-120brpm; Neonatal /Pediatric: 0-150brpm
  • Measurement Unit: Mmhg / Kpa Selectable
  • Specification: 375mm(W)*330mm(H)*180mm(D)
  • HS Code: 9018909000
Product Description
YSF8-s Multi-Parameter Monitor(12.1 inches)
 
Features
l 12.1'color TFT LCD screen 
l Acoustic and visual alarm
l Display mode: Standard, Large Font, NIBP Trend, Trend Table, Full lead ECG, Oxy CRG 
l Drug calculation and titration table 
l Real time ST segment analysis, pacemaker detection and Arrhythmia analysis 
l Suitable for monitoring adult, pediatric and neonatal patient 
l Supporting storage of 240 hours patient data, 1024 NIBP records and 1024 alarm event 
l Isolated against defibrillation effect 
Standard Configuration:
l 3-lead or 5-lead ECG/HR, RESP, Dual TEMP, SpO2/PR, NIBP 
Optional Configuration:
l Touch screen, Printer, Trolley, Wall-mount
 
 
Physical Specifications
Dimension and weightDimension375mm(W)*330mm(H)*180mm(D)
Weightstandard configuration: 4.4 kg
Operation environmentPower requirementsAC 90-300V, 50/60HZ, 60W
Power90VA
Temperature0-40ºC
Humidity 0-93% non-condensing
SafetyMeet the requirements of IEC60601 series
Patient rangeAdult, neonate and pediatric patients
Performance Specification
Display                            12.1 inch (800 x 600 pixel) color TFT LCD rolling and refreshing waveform display
Display modeStandard, large font, trend table, full lead ECG, Oxy CRG,NIBP trend
Interface
 
Parameter cable interface 
AC power input socket 
BatteryRechargeable battery, 2.2 Ah 12V
Alarm indicatorVisual on-display and integrated alarm light
Audible alarm and personated voice reminding alarm
Data storage
 
240 hours monitoring data
1024 NIBP records storage  
1024 alarm event     
Printer
 
 
Built-in 50mm thermal printer (option),  
2 traces, print speed 25mm/s & 50mm/s    
print width:50mm
ECG
Leads type 3(option)/5-lead : I, II, III, aVR, aVL, aVF, V
Sweep speed12.5mm/s, 25mm/s 50mm/s
Gain selection×0.25, ×0.5, ×1, ×2
ECG waveform1 channels
Operation modeDiagnostic, monitor, surgery
Heart rate range0 -300bpm
Accuracy1bpm or ±1% whichever is great 
Alarm rangeAudible and visual alarm, adjustable
ST/ arrhythmiaReal time S-T segment detection, pace detection and arrhythmia analysis 
ProtectionAgainst electrosurgical interference and defibrillation
Respiration (RESP)
MethodThoracic impedance
Operation mode Auto 
Measurement rangeAdult: 0-120BrPM; neonatal /pediatric: 0-150BrPM
Apnea alarmYes
AlarmYes, audible and visual alarm ,alarm events recallable
NIBP
MethodAutomatic oscillometric
Operation modeManual/Automatic/STAT
 
Auto measure time Adjustable 
Measurement unitmmHg / kPa  selectable
Test interval1-480 minutes
Measurement range
 
 
Adult: 0-300 mmHg ;     
Child: 0-240 mmHg ;      
Infant: 0-150 mmHg
Over-pressure protection Double safety protection 
Accuracy of blood pressure      measurementThe mean error shall be less than±5mmHg
the standard deviation shall be less than 8mmHG
Resolution1 mmHg
SPO2
Measurement range0%-100%
Resolution1%
Accuracy±2% (70-100%, adult/pediatric, non-motion )
±3% (70-100%, neonate, non-motion )
±3% (70-100%, adult/pediatric/neonate, motion )
0-69% unspecified
Alarm range1-100%
Pulse rate                          Pulse range:20-300bpm
Accuracy:±3bpm(non-motion)
±5bpm(motion )
Temperature (TEMP)
TEMP range0-50ºC
Resolution0.1 ºC
Accuracy±0.1ºC  (excluding the sensor)
ChannelSingle channel. 
 
Configuration
 
Feature
Standard
Optional
SpO2NIBPPRECG/HRTEMPRESPPrinter
50mm
Trolley/Wall MountTouch
Screen
 
 









 