Home » Product List » High-frequency X-ray Machine » 20kw High Frequency X-ray Machine (YSX0314)
Product Details
20kw High Frequency X-ray Machine (YSX0314)
| Packing: | Carton |
|---|---|
| Model NO.: | YSX0314 |
| Standard: | 20kW high frequency radiography x-ray machine |
| Productivity: | 500 Sets/Year |
| Unit Price: | Negotiable |
| Shipment Terms: | By sea or by air |
| Payment Terms: | L/C,T/T,D/P,Western Union,Paypal |
| Minimum Order: | 1 Sets |
| Price Valid Time: | From Dec 16,2011 To Oct 26,2012 |
| Trademark: | YSENMED |
| Origin: | Guangzhou |
| Type: | X Ray Equipment |
| Classification: | Imaging Diagnostic Equipment |
| Power: | 20kw |
| Export Markets: | North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe |
20kW High Frequency X Ray Machine (YSX0314)
Features:
1. High precision control mode through analog & digital double-loop control: Adopting HF (≥ 30kHz)inverter circuit combined with analog & digital double-loop control mode (composed of microprocessor and PWM dedicated chip), in order to achieve high-precision high voltage output. Though power supply fluctuation may appear, steady x-rays can still be output.
2. High-precision control in radiography time: Minimum exposure time is 0.0025 second, and quick radiography is accessible at any time without the influence of power phase, thus high-quality X-ray films are easily achieved and X-ray radiation to patients is reduced.
3. High-precision tube current control: X-ray tube current using two high-frequency converter heating which is controlled by the microprocessor high-speed A / D converter sampling tube current calculate in real-time. The microprocessor control the allow load of the X-ray tube. It can be set out photographic conditions of expressing an effective X-ray tube capacity;
Technical index of main component:
Function: Radiography, single-table single tube
1. Maximum output power
Intermittent mode: 100kV, 200mA, 20kW.
2. Adjustment range of tube current\tube voltage
Tube current: Radiography 16mA~200mA.
Tube voltage: Radiography 40kV~125 kV.
3. Exposure Time: Photography0.0025s~6.4s step adjustable
4. Frequency operation≥ 30kHz
5. The condition of power
Power Voltage: 380V± 10%
Power supply capacity: 120% the power of the equipment
Internal resistance: ≤ 0.5.
6. High frequency and high voltage X-ray generator(including microcomputer control console)
Frequency operation of high voltage X-ray generator≥ 30kHz.
Internal resistance: Less than 0.5.
Output power: 20kW.
Output Voltage: Radiography: 40 kV~125kV, step 1kV;
Output Current: Radiography: 16mA~200mA,
Exposure Time: 0.0025s~6.4s.
Display: Digital pipe display photography voltage\ Photography current\ photography time\ mAS of photography
X-ray tube
Max tube voltage: 125kV Max tube current: 400mA.
Small focus: 1.0mm; Big focus: 2.0mm.
Speed of anode rotating: 2800r/min
Anode heat capacity: 140KHU
7. Collimator
Collimator with fixed position lamp.
Power supply: Working voltage: 24V
8. Radiography Bed
Integration of the bed with stand column without skyrail design.
Length*width*height of bed surface: 2000mm× 760mm× 690mm. Deviation: ± 10mm
Distance from table surface to film: 50mm
Horizontal movement distance of table≥ 220mm
Vertical movement distance of table≥ 900mm Way of locking: Manually single automatic multi-optional
9. X-ray source component pillar:
With the scaleplate indicating the height of X-ray tube source component pillar.
Distance of vertical movement: 770mm± 10mm; +90° ~-90° , deviation<± 2°
Moving crosswise (left & right): +180° ~-180° , deviation<± 2°
Moving lengthways (along ground railway) ≥ 1300mm
10. Ray-filter of table: Fixed beam filtration grid density≥ 40 lines/cm.
Ray-filter grid: Grid ratio 10: 1, . Focus Distance: 110cm
11. Horizontal movement of bucky ≥ 500
Braking Force of electromagnetic≥ 98N, Button operation.
12. Limited beam splitter start and closedown should portable, flexible, reliable, can adjust to any Radiation field rectangle size.
13. Fixed beam filtration grid density≥ 40 lines/cm.
Ray-filter grid: Grid ratio 10: 1, Focus Distance: 110cm
Cassette size: 53× 73 83× 103 103× 123 113× 143 143× 173
Product Configuration:
X-ray tube, 1 set
Radiography Table, 1 set
Collimator, 1 set
High-voltage generator, 1 set
Micro console, 1 set
High-voltage cable, 2 pieces
Vertical bucky stand (Optional), 1 set
Inquiry Basket (