• Medical Equipment Ysesu-2000b Surgical Generator Instrument Electrocoagulation
  • Medical Equipment Ysesu-2000b Surgical Generator Instrument Electrocoagulation
  • Medical Equipment Ysesu-2000b Surgical Generator Instrument Electrocoagulation
  • Medical Equipment Ysesu-2000b Surgical Generator Instrument Electrocoagulation
  • Medical Equipment Ysesu-2000b Surgical Generator Instrument Electrocoagulation
  • Medical Equipment Ysesu-2000b Surgical Generator Instrument Electrocoagulation

Medical Equipment Ysesu-2000b Surgical Generator Instrument Electrocoagulation

Type: Electrosurgical Unit
Kind: Electrosurgical Unit
Certification: CE, ISO13485, Electrocoagulation
Group: All
LCD Display: With LCD Display
Bipolar Cut: 1W~120W( Load 200Ω)
Customization:
Diamond Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
YSESU-2000B
Contact Coag
1W~80W( Load 800Ω)
Pure Cut
1W~300W( Load 800Ω)
Power Rating
1100va±10%
Bipolar Coagulation
1W~70W( Load 200Ω)
Forced Coag
1W~120W( Load 800Ω)
Blend1
1W~200W(Load 800Ω)
Operating Frequency
416kHz for Bipolar Electrocoa
Blend2
1W~250W(Load 800Ω)
Transport Package
Standard Export Wooden Case
Specification
ISO certificate
Trademark
ysenmed
Origin
China
Production Capacity
500set/Month, Electrocoagulation

Product Description

Medical Ysesu-2000b Surgical Generator Instrument Electrocoagulation

Medical Equipment Ysesu-2000b Surgical Generator Instrument Electrocoagulation

 Medical Equipment Ysesu-2000b Surgical Generator Instrument Electrocoagulation

 Main Features:
a)  Deep hemostasis, foot control outputs, mild hemostasis.
a)  Deep hemostasis, foot control outputs, mild hemostasis.
b) According to the depth of hemostasis, the output mode stops automatically. The output power will not reduce when operating in dry and bleeding spot.
c)Foot control mode: When the tissue reach the coagulation effects, the output power declines slowly.
d) Auto mode: when the tissue or blood vessel was coagulated, output power drops off sharply, to keep the forceps from sticking and over burnt for tissues.
e) Low voltage effectively reduces forming of the sparking of forceps, stimulating for the neuromuscular, to increase the security.
f)  Microcontroller system allows this unit can be used in many delicate surgery.
g)  Bipolar cut :macro bipolar.
 
Technical specifications 
1) Two working modes: bipolar coag,bipolar cut
 
2) Power: 220V±22V(110V±11V) 50Hz±1Hz
 
3) Working frequency:1024KHz
 
4)Output power:
 
  a) bipolar coag:1-120W(load 200Ω)
 
  b) bipolar cut:1-120W(load 200Ω)
Configuration For  Electrosurgical Unit
 
Footswitch                                                  1set
 
None sticky bipolar Forceps and cable           1set
 
Bipolar cut  pencil                                       1piece
 
 Medical Equipment Ysesu-2000b Surgical Generator Instrument Electrocoagulation
Medical Equipment Ysesu-2000b Surgical Generator Instrument Electrocoagulation
Medical Equipment Ysesu-2000b Surgical Generator Instrument Electrocoagulation
Medical Equipment Ysesu-2000b Surgical Generator Instrument Electrocoagulation
Medical Equipment Ysesu-2000b Surgical Generator Instrument Electrocoagulation
Medical Equipment Ysesu-2000b Surgical Generator Instrument Electrocoagulation

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now