  • Model NO.: YSAV90A
  • Medical Devices Ad. Approval No.: Gsyjxzz2013-3540437
  • Display Mode: 10.4′′ LCD Display
  • Techniques Specifications Physical Spec: <12.5 Kpa
  • Warranty Period: 12 Months
  • Gas Requirement: Oxygen with a Pressure Ranging From 280~600kpa
  • Pressure Limit Range: 1.0~ 6.0kpa
  • Transport Package: Wooden Case
  • Origin: China
  • Medical Device Regulatory Type: Type 3
  • out Looking: Mobile
  • Certificate: Ce, ISO
  • Ptr: -10 ~ 10 Hpa
  • Inspiratory Plateau: 0~1s
  • I/E Ratio: 4:1~1:4, Has The Inverse Ratio Ventilation
  • Trademark: YSENMED
  • Specification: CE certificate
Product Description
 YSAV90A hospital surgical room mobile medical respirator 

 
TECHNIQUES SPECIFICATIONS
Physical specifications
Display10.4'' LCD Display
Mode:pneumatically powered and electrically controlled system
Trolley:Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions
Technical Specifications:
Gas requirement:Medical oxygen and nitrous oxide with a pressure ranging from 280~600kpa
safety valve<12.5 kPa
Respiratory Rate1 ~ 99 bpm
gas concentration output21% ~ 100% adjustable
Maximum Minute ventilation≥18L / min
modes of ventilationA/C, SIPPV,IPPV,SIMV,PSIMV,CPAP,PCV,PEEP,SIGN,SPONT, MANUAL
Ventilator compliance≤30 Ml/kPa
PEEP:0 ~ 1.0 kPa
Ptr:-10 ~ 10 hPa
IMV frequency:1~20 bpm
I/E Ratio:4:1~1:4, Has the inverse ratio ventilation
Tidal VolumeSetting Range: 50~1500ML     Display Range: 0~2000ml ;   resolution ratio: 10ml
Inspiratory Plateau:0~1s
Maximum Safety Pressure≤ 6.0kPa
Sigh:one deep breath per 80 controlled respirations, the inspiration time is 1.5 times of the setting point
Pressure limit range:1.0~ 6.0kPa
Airway pressure alarm: Audible and visual and with yellow and red color indicatingLower: 0.1 kPa ~ 6.0 kPa;   Upper: 0 ~ 5.0 kPa
±0.2 kPa
Ventilation Volume alarm:≥ 18L/ MIN
Power Supply AlarmAc/dc power supply are after failing to send out alarm immediately
Alarm Time: keep >120s
The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm, the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic respirator.
Operating conditions
Ambient temperature:10 ~ 40oC
Relative humidity:no higher than 80 %
Atmospheric pressure:860 hPa ~ 1060 hPa
Power requirement:100-120 Vac, 50/60 Hz; 
Attention: the AC power supply used for the anesthesia machine must be well     grounded.
Attention: the anesthesia machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993, an oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical Electrical Equipment Part II: Special Requirements for Safety and Basic Performance of Anesthesia System.
Storage
Ambient temperature:-15oC ~ +50oC
Relative humidity:no higher than 95 %
Atmospheric pressure:86 kPa ~ 106 kPa.
 It should be stored in a room without corrosive gas and well ventilated
Package
packaging boxcomply with the requirement of GB/T 15464
 Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportation
 Moisture protection and rain protection to ensure that product is protected from natural damage.
Safty & Alarm
Gas source pressureImmediate alarm; "high level alarm" indicator flickers raising an audible alarm.
Airway Pressure AlarmThe airway pressure exceeds 15hpa. The maximum delay is no longer than 17s. The "high level alarm" indicator flickers raising an audible alarm.
Tidal Volume AlarmLower than 50ml, The alarm will be raised after one breathing cycle.
Ventilation Volume AlarmLower: 0~12L/Min;   Up: 18L/ Min
Battery Voltage AlarmIt alrms when the battery voltage is lower than 10.5V.
Power On Self TestSelf test before working, assure it's working normally.
STANDARD CONFIGURATIONS
QTYNAME
1 setMain unit
4 pcsAdult threaded pipe (Silica)
1 setChild threaded pipe (single use)
1 pcOxygen Tube
1pcY-Pipe
2pcsMask (Silicom)
2pcsLeather Bag
2pcsFuse
1pcPower Line
1pcOxygen pressure reducer
4 pcsHoop
1pcBattery
1pcTools Attachment
1 sethumidifier
1 setEnglish Version User Manual
 

We are a company aiming to make one stop shopping for our customers. We equiped hospital
operation room with many kind of items like operation table, orthopedic drill and saw, ECG,
defibrillator etc.
We listed some hospital operation room items basic items for your reference as below:
operation roomanesthesia machine
ventilator
operating lamp
operation table
Pendant
medical drill and saw
ECG
patient monitor
Defibrillator
infusion pump
Electrocoagulation
oxygen generator
electric suction device
autoclave sterilizer
 
 
Contact person: Selin Liao
Tel: 86-20-34174605/34174486
Mob: 86-18814108686
 
 
 
Product Groups
Send your message to this supplier
Avatar
Ms. Selin Liao
International Sales
*From:
To: Ms. Selin Liao
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

Find Similar Products By Category