• Ysf5 Portable Multi-Parameter Patient Monitors

Ysf5 Portable Multi-Parameter Patient Monitors

Type: Anaesthesia Machine
Certification: CE
Group: Children
Extended Advance Function: 2IBP, Depth of Anesthesia
ECG: 3/5-Lead
Transport Package: Carton
Customization:
Diamond Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
YSF5
Trademark
YSENMED
Origin
China
Production Capacity
5, 000 Sets/Year

Product Description

YSF5 Portable Multi-Parameter Patient Monitors
Ysf5 Portable Multi-Parameter Patient Monitors
Physical Specifications
Dimension and weight Dimension 340mm(W)*280mm(H)*130mm(D)
Weight Standard configuration: 4 kg
Operation environment Power requirements AC 100-240V, 50/60HZ, 60W
Power 90VA
Temperature 0-40ºC
Humidity 0-93% non-condensing
Safety Meet the requirements of IEC60601 series
Patient range Adult, neonate and pediatric patients
Performance Specification
Display                             12.1' (800 x 600 pixel) color TFT LED screen
Display mode Standard, big font, trend table, full-lead ECG, Oxy CRG.
Interface
 
Parameter cable interface
AC power input socket
Network interface
Battery 1 internal large capacity rechargeable lithium battery
Alarm indicator Visual on-display and integrated alarm light
Audible alarm
Data storage
 
108 hour trend graph
168 hour trend table 
2 hour trend wave  
1024 alarm events  
Printer

 
Built-in 50mm thermal printer (option),  
3 traces, print speed 12.5mm/s & 25mm/s & 50mm/s    
Print width: 50mm
Net working Support connection to central monitoring station through LAN (TCP/IP) or wireless connection   
ECG
Leads type 3/5 lead : I, II, III, aVR, aVL, aVF, V
Sweep speed 12.5mm/s, 25mm/s,50mm/s
Gain selection ×0.25, ×0.5, ×1, ×2, Auto
ECG waveform 2 channels
Operation mode Diagnostic, monitor, surgery
Heart rate range 0 - 350bpm
Accuracy 1bpm or ±1% whichever is great
Alarm range Audible and visual alarm, adjustable
ST/ arrhythmia Real time S-T segment detection, pace detection and arrhythmia analysis
Protection Against electrosurgical interference and defibrillation
Respiration (RESP)
Method Thoracic impedance
Operation mode Auto
Measurement range Adult: 0-120BrPM; neonatal /pediatric: 0-150BrPM
Apnea alarm Yes
Alarm Yes, audible and visual alarm ,alarm events recallable
NIBP
Method Automatic oscillometric
Operation mode Manual / Automatic / STAT
Auto measure time Adjustable
Measurement unit mmHg / kPa  selectable
Test interval 1-480 minutes
Measurement range

 
Adult: 0-300 mmHg ;     
Child: 0-240 mmHg ;      
Infant: 0-150 mmHg
Over-pressure protection Double safety protection
Accuracy of blood pressure      measurement The mean error shall be less than ± 5mmHg
The standard deviation shall be less than 8mmHG
Resolution 1 mmHg
SPO2
Measurement range 0%-100%
Resolution 1%
Accuracy ±2% (70-100%, adult/pediatric, non-motion )
±3% (70-100%, neonate, non-motion )
±3% (70-100%, adult/pediatric/neonate, motion )
0-69% unspecified
Alarm range 1-100%
Pulse rate                           Pulse range: 0-350bpm
Accuracy: ±3bpm(non-motion)
±5bpm(motion )
Temperature (TEMP)
TEMP range 0-50ºC
Resolution 0.1 ºC
Accuracy ±0.1ºC  (excluding the sensor)
Channel Dual-channel. provide T1;T2; T
IBP
Measurement range -50-360mmHg
Channel 2 channels
Pressure transducer Sensitive :5 uV/V mmHg
Impedance range :300-3000 Ω
Pressure names ART, PA, CVP, RAP, LAP, ICP, P1, P2
Alarm range -10-300 mmHg
PR from IBP Range & Accuracy: 25-200bpm  ±1bpm or ±1bpm which is greater
201-350bpm ±2%
Resolution : 1bpm
Depth of Anesthesia (BIS) 
EEG sensitivity +/- 475μV
Noise < 2uVp-p (1-150 Hz)
CMRR > 100 dB
Input impedance > 50mohm
Sample rate 1024 samples/s, 16 bits
Ysf5 Portable Multi-Parameter Patient Monitors
Ysf5 Portable Multi-Parameter Patient Monitors
Ysf5 Portable Multi-Parameter Patient Monitors
Ysf5 Portable Multi-Parameter Patient Monitors





    
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now