Guangdong, China
Business Type:
Trading Company
Terms of Payment:
LC, T/T, Western Union
OEM/ODM Availability:
OEM/ODM Service

Mammography Machine, X-ray Machine, Medical Equipment manufacturer / supplier in China, offering Hospital Medical X-ray Mammography Machine, Yste168V Medical Veterinary Semi Automatic Biochemistry Analyzer, Ysvet8103 Manufacturer Annimal Cage Medical Veterinary Stainless Steel Dog Cage and so on.

Gold Member Since 2010
Audited Supplier

Hospital Medical X-ray Mammography Machine

Get Latest Price
Min. Order: 1 Set
Production Capacity: 500 Sets/Year
Transport Package: Wooden Box
Payment Terms: L/C, T/T, Money Gram, Western Union
Classification: Imaging Diagnostic Equipment
Type: X Ray Equipment
Certification: ISO13485
Group: All
Generator Type: High Frequency Inverter 40kHz
Input Power: Single Phase 220VAC, 50/60Hz

You Might Also Like


Basic Info

Model NO.: YSX980D
Radiographic Ratings: Large Focal Point 20-35kv/1-300mas
Small Focal Point: 20-35kv/1-100mas
Power Rating: 1.2kw
Trademark: YSENMED
Specification: ISO certificate
Origin: China
HS Code: 9022199090

Product Description

High frequency mammography x-ray machine YSX980D





X-ray Generator 

Generator Type:High Frequency Inverter 40kHz
Input Power:Single phase 220VAC, 50/60Hz
Radiographic Ratings:Large Focal Point 20-35KV/1-300mAs
Small Focal Point 20-35KV/1-100mAs
Power Rating:1.2kW 



X-ray Tube 

Model:Fixed anode,China Hang Zhou XD7(X791)
Focal Spot Size:Dual Focus 0.5mm
Target Material:Molybdenum (Mo)
Port Material:Beryllium (Be)
Anode Heat Storage:63KHU
Anode Cooling:Air cooling



Radiographic Stand 

C-ARM: Vertical Movement:60cm (70~130cm) Motorized
Rotations Deg:±180° Motorized (Deg. Data Display)
SID: 65cm



Cassette Image Receptor: 18×24cm 



Line Voltage:220Vac@15A,Single phase






Bucky: (Optional)
Bucky Device:18×24cm Bucky drive mechanism
Grid Ratio:3.5:1,30 Line/cm


Comfortable Compression(Optional)

 When some degree of pressure is required for radiography, it allows you to 

press appropriate pressure(up to a maximum of 20kg and is equipped with 

MICOM Control's Soft-touch system which is designed to minimize the 

discomfort of the examine with in the pressure range.



Tissue Compression: Manual and Motorized (Max 20kg)
Compression Force and Thickness Data Display

Micom Control's Compression
Automatic Release



Intelligent Automatic Exposure Control (AEC) (Optional) 

With the Automatic Exposure Control system, it is possible to produce images with 

reliable intensity suitable for and film, screen, or method of radiography. 


Furthermore, it greatly enhances the convenience of radiography by embedding the 

Full-AEC function which is capable of utilizing the Auto kV

AEC Mode: Full AEC(Auto kV)
Semi AEC (KV Select)
Manual (kV, mAs Select)

Type: Solid-State Detector or PMT Detector
Microprocessor Control

Density Adjustment: 10 density steps

Hospital Medical X-ray Mammography Machine
Hospital Medical X-ray Mammography Machine
Hospital Medical X-ray Mammography Machine

Send your message to this supplier

avatar Mr. Andy Guo

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like


Product Groups

Contact Supplier

Mr. Andy Guo
Sales Manager