Surgical Ysav70b Instrument Mobile Emergency Medical Anesthesia Ventilator

Product Details
Customization: Available
Type: Anesthesia Ventilator
Tidal Volume: 0-1500ml
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Terms of Payment
LC, T/T, Western Union, Money Gram
OEM/ODM Availability
Yes
Find Similar Products

Basic Info.

Model NO.
YSAV70B
Maximum Minute Ventilation
≥18L / Min
Peep
0 ~ 1.0 Kpa
Maximum Safety Pressuret≤ 6.0kpa
≤ 6.0kpa
Sigh Volume
150% of Tidal Volume
Respiratory Rate
1 ~ 99 Bpm
Modes
Ippv, Sippv, Imv, Simv, Psimv, CPAP, Vcv, Pcv
Air Flow Adjustment
1-12times
Ptr Range
-0.8~0.9kpa
Certification
Ce, ISO13485, Veterinary Anesthesia Ventilator
Group
All
Transport Package
Standard Export Wooden Case
Specification
CE certificate
Trademark
ysenmed
Origin
China
Production Capacity
100PCS/Month, Veterinary Anesthesia Ventilator

Product Description

Surgical YSAV70B  Instrument Mobile Emergency Medical Anesthesia Ventilator
Model:   YSAV70B

Surgical Ysav70b Instrument Mobile Emergency Medical Anesthesia Ventilator

 

The YSAV70B ventilator is gas driven by medical compressed oxygen and compressed

air. In the inspiratory phase, two streams of compressed gas (compressed oxygen and

compressed air) flow into a high performance air-oxygen mixer to form a mix of oxygen

and air with a certain pressure.

 

Maximum Minute ventilation ≥18L / min
modes of ventilation A/C, IPPV, SIPPV, IMV, SIMV, PEET. MANUAL, SIGH, SPONT
Ventilator compliance ≤30 Ml/kPa
PEEP: 0 ~ 1.0 kPa
Ptr: -10 ~ 10 hPa
IMV frequency: 1~20 bpm
I/E Ratio: 4:1~1:4, Has the inverse ratio ventilation
Tidal Volume Setting Range: 50~1500ML     Display Range: 0~2000ml ;   resolution ratio: 10ml
Inspiratory Plateau: 0~1s
Maximum Safety Pressure ≤ 6.0kPa
Sigh: one deep breath per 80 controlled respirations, the inspiration time is 1.5 times of the setting point
Pressure limit range: 1.0~ 6.0kPa
Airway pressure alarm: Audible and visual and with yellow and red color indicating Lower: 0.1 kPa ~ 6.0 kPa;   Upper: 0 ~ 5.0 kPa
±0.2 kPa
Ventilation Volume alarm: ≥ 18L/ MIN
Power Supply Alarm Ac/dc power supply are after failing to send out alarm immediately
Alarm Time: keep >120s
The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm, the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic respirator.
Operating conditions
Ambient temperature: 10 ~ 40oC
Relative humidity: no higher than 80 %
Atmospheric pressure: 860 hPa ~ 1060 hPa
Power requirement: 100-120 Vac, 50/60 Hz; 
Attention: the AC power supply used for the anesthesia machine must be well     grounded.
Attention: the anesthesia machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993, an oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical Electrical Equipment Part II: Special Requirements for Safety and Basic Performance of Anesthesia System.
Storage
Ambient temperature: -15oC ~ +50oC
Relative humidity: no higher than 95 %
Atmospheric pressure: 86 kPa ~ 106 kPa.
  It should be stored in a room without corrosive gas and well ventilated
Package
packaging box comply with the requirement of GB/T 15464
  Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportation
  Moisture protection and rain protection to ensure that product is protected from natural damage.
Safty & Alarm
Gas source pressure Immediate alarm; "high level alarm" indicator flickers raising an audible alarm.
Airway Pressure Alarm The airway pressure exceeds 15hpa. The maximum delay is no longer than 17s. The "high level alarm" indicator flickers raising an audible alarm.
Tidal Volume Alarm Lower than 50ml, The alarm will be raised after one breathing cycle.
Ventilation Volume Alarm Lower: 0~12L/Min;   Up: 18L/ Min
Battery Voltage Alarm It alrms when the battery voltage is lower than 10.5V.
Power On Self Test Self test before working, assure it's working normally.
 

Surgical Ysav70b Instrument Mobile Emergency Medical Anesthesia Ventilator
Surgical Ysav70b Instrument Mobile Emergency Medical Anesthesia Ventilator
Surgical Ysav70b Instrument Mobile Emergency Medical Anesthesia Ventilator
Surgical Ysav70b Instrument Mobile Emergency Medical Anesthesia Ventilator
Surgical Ysav70b Instrument Mobile Emergency Medical Anesthesia Ventilator
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More