• Medical Equipment 15-Inch Display Medical Multi-Parameter Patient Monitor
  • Medical Equipment 15-Inch Display Medical Multi-Parameter Patient Monitor
  • Medical Equipment 15-Inch Display Medical Multi-Parameter Patient Monitor
  • Medical Equipment 15-Inch Display Medical Multi-Parameter Patient Monitor
  • Medical Equipment 15-Inch Display Medical Multi-Parameter Patient Monitor
  • Medical Equipment 15-Inch Display Medical Multi-Parameter Patient Monitor

Medical Equipment 15-Inch Display Medical Multi-Parameter Patient Monitor

Type: Multi Parameter Patient Monitor
Support Display: Maximum 8 Waveforms
Name: Portable Vet Patient Monitor
ECG Waveform Display: 6 Channel
Adapter: Output 13-20V DC, 5A
Resolution: 800*600 Pixels
Customization:
Diamond Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
YSPM-15B
LED
8.0 Inch
Printer
Built-in High-Speed 50 mm Thermal Printer
Temperature
  -20~50 ºC
Humidity
  10%~90%
Transport Package
Carton
Trademark
YSENMED
Origin
Guangzhou
Production Capacity
1, 000 Sets / Year

Product Description

Medical Equipment 15-inch Display Medical Multi-parameter Patient Monitor
Medical Equipment 15-Inch Display Medical Multi-Parameter Patient Monitor

Features:
·15.6 inch high-brightness TFT LED
·Support display maximum 8 waveforms
·Support 6 channel ECG waveform display simultaneously 
·Support storage of 168 hours trend table and graph review
·100 minutes waveform review
·500 groups NIBP review
·100 hours of parameter alarm events review and associated parameters
 

 Medical Equipment 15-Inch Display Medical Multi-Parameter Patient Monitor

Operating Environment
-  Temperature:  5 ~ 40 ºC
-  Humidity:  15% ~ 80% (non-condensing)
-  Atmosphere pressure:  86 KPa ~ 110 KPa

Transportation and Storage Environment
-  Temperature:  -20~50 ºC
-  Humidity:  10%~90%  (non-condensing)
-  Atmosphere pressure:  86 KPa ~ 110 KPa
 
Safety
-  IEC60601-1 Approved, CE marking according to MDD93/42/EEC
-  With reference to RoHS Directive 2011/65/EU recasting
 
Trend & Reviewing
-  Trend: 168 hours
-  NIBP measurement reviewing: 500 groups
-  Waveform review: 100 minutes
-  Alarm event: 100hours of parameter alarms events and associated parameter
 
ECG
-  Lead mode: 3/5 Leads, I, II, III or I, II, III, AVR, AVL, AVF, V
-  Gain: 2.5mm/mV(×0.25), 5.0mm/mV(×0.5), 10mm/mV (×1), 20mm/mV (×2),
-  Sweep speed: 6.25 mm/s12.5 mm/s, 25 mm/s, 50 mm/s
-  ECG signal range:  ±6 mV
-  Accuracy: ±1bpm/ ±1%, whichever is greater
-  Resolution: 1 bpm
-  Leakage Current < 10 μA
-  Input impedance: > 5.0Mohm
-  CMRR: Diagnostic Mode >90 dB;
       Monitor Mode>100dB
       Surgery Mode>100dB
-  Baseline Recovery: ≤ 5s after defibrillation (Monitor or Surgery mode)
-  Bandwidth: Surgery 1 ~ 20Hz
   Monitor 0.5 ~ 40 Hz
   Diagnostic 0.05 ~ 130 Hz
-  Against electrosurgical interference and defibrillation
-  Indication of Electrode Separation: Every electrode (exclusive of RL)
 
Heart Rate
-  Measure range:
    Big animal 0bpm; 15 ~ 300 bpm
    Small and middle: 0bpm; 15 ~ 450 bpm
-  Resolution: 1 bpm
-  Accuracy: ± 1% or ± 1bpm, whichever is greater

ST Measurement
-  Range: -2.0 ~ +2.0 mV
-  Accuracy: -0.8mV~+0.8mV: ±0.02mV or ±10%, whichever is greater
-  Other range: unspecified
 
Respiration
-  Method: Impedance between RA-LL,
-  Gain: ×0.25, ×0.50, ×1, ×2,
-  Respiration Rate: 0bpm, 0 ~ 150 BrPM
-  Sweep speed:  6.25 mm/s, 12.5 mm/s, 25mm/s
-  Resolution: 1 BrPM
-  Accuracy: ±2 bpm or ±2%, whichever is greater
-  Apnea Alarm: 10 ~ 40 s
 
NIBP
-  Method: Oscillometric
-  Measure mode: Manual, Auto, STAT
-  Measure Interval in AUTO Mode 1~480 min
-  STAT mode cycle time: Keep 5 minutes, at 5 seconds interval
-  Measure and Alarm Range:
Big animal: SYS:  40 ~ 270 mmHg
                    DIA:  10 ~ 215mmHg    
                    MEAN:  20 ~ 235 mmHg
Middle animal: SYS:  40 ~ 200 mmHg
                          DIA:  10 ~ 150mmHg    
                          MEAN:  20 ~ 165 mmHg
Small animal: SYS:  40 ~ 135 mmHg
                        DIA:  10 ~ 100mmHg    
                        MEAN:  20 ~ 110 mmHg
-  Static pressure accuracy: ±3mmHg
-  Resolution: 1mmHg
-  Accuracy: Maximum Mean error ±5mmHg          
         Maximum Standard deviation ≤8mmHg
-  Over pressure Protection: Dual protection via software & hardware
 
Temperature
-  Technique: Thermistor probe (2.25K)
-  Channel:  Dual-channel, provide T1; T2; ΔT
-  Measuring and Alarm Range: 0.0 ºC~ 50 ºC (32ºF~ 122ºF)
-  Unit: Celsius (ºC), Fahrenheit ( ºF)
-  Resolution: 0.1ºCor 1ºF
-  Accuracy: ±0.1ºC(exclusive probe)

Performance Specifications:
SpO2 (Analog Technic) 
-  Measurement Range: 0 ~ 100 %
-  Resolution: 1 %
-  Accuracy:  ±2% (70% ~ 100%)
Unspecified (0 ~ 69%)
 
Pulse Rate
-  Measuring and Alarm Range: 20~450bmp
-  Accuracy: ±3%
-  Resolution: 1bpm
 
EtCO2 (Mainstream/ Sidestream) (Option)
-  Measure method:  Non-dispersive infrared (NDIR)
-  Measure Range:  0 ~19.7% (0 ~ 150 mmHg)
                 0 ~ 20 kPa
-  Resolution: 0.1 mmHg
-  CO2 Accuracy: 0 ~ 40 mmHg, ±2 mmHg 41 ~ 70 mmHg, ±5% of reading  71 ~ 100 mmHg, ±8% of reading 101~ 150 mmHg, ±10% of reading at 760 mmHg, ambient temperature of 25ºC)
-  Respiratory Rate:  Range: 3 ~150 BrPM Accuracy: ±1 bpm
 

 
Medical Equipment 15-Inch Display Medical Multi-Parameter Patient Monitor





Medical Equipment 15-Inch Display Medical Multi-Parameter Patient Monitor


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Product Groups

Diamond Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Terms of Payment
LC, T/T, Western Union, Money Gram
OEM/ODM Availability
Yes