Customization: | Available |
---|---|
Type: | Diagnostic Set |
Syringe: | Analyzer |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Features:
Rebound tonometer, also known as impact tonometer, adopting an innovative sensing rebound technology. The probe will be magnetized when being inserted into the tonometer and generates N/S poles. An transient current in the solenoids of the device (lasting about 30 milliseconds) produces an transient magnetic field that causes the magnetized probe to move towards the cornea at 0.2m/s (homopolar repulsion principle). The probe bounces on the anterior surface of the cornea, slowing down and rebounding. If the ocular pressure is increased, the decelaration of the probe increases, and the duration of the impact decreases.
The electrical control switch monitors the solenoid voltage caused by the rebound of the magnetized probes,and the electrical signals processors and the microsensors calculates the deceleration of the probe after impacting the cornea. Finally the integrated information is converted into ocular pressure readings.
Rebound tonometer is an electric measuring type pressure guage which converts the presurre into the voltage or current signal through the physical characteristics of the metal.
Tonometer can obtain the measurement data within 0.1secons.
Applicability:
1. Used in tonometery tests by ophthalmologists,optometrists,general physician,professional health advisors.
2. Better for patients with dementia,mobility problems and children in the measurement of cornea edema,opacity or uneven cornea surface.
3. Handy of glaucoma patients in measuring ocular pressure at home.
Usage:
1. Turn on the tonometer and install the probe.
2. Move the machine close to the eyes and adjust the distance
3. Gently press the button and obtain the single measurement vaules and average values in several times.
*Short measuring time ,only seconds.
*Reduce the check time for glaucoma.
*Capacable of storing the ocular data of some ten patients.
Measuring Current | 0-6A |
Measuring Voltage | DC3V |
Measuring Range | 3mmHg~70mmHg |
Weight | 300g |
Max Probe Speed | 0.2m/s |
Product Dimensions | 110mmx190mmx30mm |
Package Dimensions | 240mmx280mmx90mm |
Working Temperature Range | +5ºC~+40ºC |
Working Humidity Range | ≤80% |
Working Atmospheric Range | 700 hpa~1060hpa |
Storage Temperature Range | -20ºC~+55ºC |
Storage Atmospheric Range | 500 hpa~1060hpa |
Storage Humidity Range | ≤95% |
Accuracy Class(3mmHg≤intraocular pressure≤25mmHg) | ±1.5mmHg |
Accuracy Class(25mmHg≤intraocular pressure≤70mmHg) | ±2.5mmHg |