Fully Automated Chemistry Analyzer, Biochemistry Analyzer, Analyzer manufacturer / supplier in China, offering Yste180c Medical Fully Automated Chemistry Analyzer, Yste168V Medical Veterinary Semi Automatic Biochemistry Analyzer, Ysvet8103 Manufacturer Annimal Cage Medical Veterinary Stainless Steel Dog Cage and so on.

Gold Member Since 2010
Audited Supplier

Yste180c Medical Fully Automated Chemistry Analyzer

Get Latest Price
Min. Order: 1 Set
Port: Guangzhou, China
Production Capacity: 1, 000 Sets / Year
Payment Terms: L/C, T/T, Western Union, Money Gram
Classification: Biochemical Apparatus
Type: Biochemistry Analyzer
Certification: ISO13485
Group: All
Temperature: 10-30 Degree
Barometric: 86.0kpa-106.0kpa.

You Might Also Like


Basic Info

Model NO.: Yste180c
Water Consumption: Less Than 6L/H.
Power Supply: AC 220V±22V 50Hz±1 Hz.
Humidity: More Than 70%
Frequency: 550 Va.
Weight: 60kg
Dimension: 782mm×581mm×545mm
Trademark: YSENMED
Transport Package: Wooden Carton
Specification: CE certificate
Origin: Guangzhou

Product Description

Medical Full Automatic Chemistry Analyzer Yste180c

Automatic Chemistry Analyzer

Throughput constant 180 T/h or 300T/h, best for middle or small size hospital
Closed integrated photovoltaic systems, no mechanical parts, maintenance free
Minimum reaction volume is 150UL, cost saving
Discrete, random access, automatic
Random choice of method, the real discrete automatic chemistry analyzer
This automatic chemistry analyzers have gained a lot of national patents during the researching.

Analyze Unit
L Throughput: Constant 180 T/h, 81 reaction cuvette positions, multi-channel testing together.
L Minimum reaction volume is 150μ L, cost saving.
L Determined by the sample sequence, inserted at any time emergency.
L Heating method: Direct thermal solid thermostat closed.

Optical Unit
L Closed integrated photovoltaic systems, no mechanical parts, maintenance free.
L Light Source: Halogen-tungsten lamp;
L Lifetime≥ 2000 h.
L 8 Wavelength, support single or dual wavelength.

Reagent Unit
L 60 reagent positions.
L Automatically detect the amount of reagent remaining, displayed in real time the remaining amount of reagent.
L 15ml, 20ml, 30ml, 50ml or 70ml reagent bottle. Dead volume <1.0 ml.
L Support for single and double reagent, reagent completely open.
Internal barcode reader (option).

Sample Unit
L 60 sample positions.
L Testing according setting, random access.
L Real time display of testing status.
L Internal barcode reader (option).

Reagent/Sample handing Unit
L Intelligent liquid detection & collision protection (Red light: Collision; Blue light: Detection of the liquid).
L Reagent volume: 2 ~ 500μ L, step by 1μ L.
L Probe cleaning: Automatically washing for both inside and outside, carry over0.1%.
L Automatically dilute and retest.

Calibration and quality control Unit
L Linear curve type: Single-point linear, two-point linear and multi-point linear.
L Nonlinear curve type: Logit-4p, Logit-5p, polynomial, factor.
L Automatically use best calibration curve and standard.
L Quality control chart: L-J, Westgard TwinPlot, Cumulative.

Operation Unit
L Operation system: Windows XP/Office 2000, interface is intuitive and operate it easily, arbitrary operating authority; No restrictions on the amount of time and storage, permanent preservation of various types of data, automatic storage and backup.
L Can print the contents of any custom; Offers a variety of print formats.
L Help and operation guide on line in English.
L No restrictions on setting test parameters.
L Unique password for user management, rational allocation of user rights.
L Real time display of testing status, the remaining amount of reagent, testing status, reaction curve and the test progress.
L Real time display of reaction plate temperature.
RS-232 standard interface, support for the hospital network, print reports remotely.

L Temperature: 10-30 degree
L Humidity: Less than 70%.
L Try to avoid strong light.
L Floor level up: Less than 1/200.
L Barometric: 86.0kPa-106.0kPa.
L Power Supply: AC 220V± 22V 50Hz± 1 Hz.
L Water consumption: Less than 6L/h.
L Frequency: 550 VA.
L Dimension: 782mm× 581mm× 545mm
L Weight: 60kg

Test projects

Ysenmed ® Yste180c
Automatic Chemistry Analyzer
Analyze Unit
ThroughputConstant 180T/h (non-ISE)
TheoryAbsorption spectrometry, transmission turbidimetry
MethodologyEnd-point \Fixed-time\Kinetic\Ion selective electrode
Test according set up, random access
Reaction plateContain 81 reaction cuvettes
Maximum reaction time15 minutes
Minimum reaction volume150 ul
Material of cuvettesSpecial UV-transparent optical glass
Cuvettes useAutomatically cuvettes washing
Optical Unit
Light SourceHalogen-tungsten lamp
PhotometerReversed optics
Wavelength340nm-900nm wavelength option
Absorption0-4 Abs
Reagent Unit
Reagent plate60 reagent positions ,support for single and double reagent, reagent completely open
Reagent storage temperature2~10 degree
Reagent bottle15ml, 20ml, 30ml, 50ml or 70ml ,dead volume is less than 1.0 ml
Reagent volume20-500 ul, step by 1.0 ul
Reagent/Sample ProbeAutomatically checked ;Patent technology liquid level detection;Collision protection probe cleaning:Automatic washing for both inside and outside.
Sample Unit
Sample plate60 sample positions
Sample typeHuman (animal) serum \plasma\urine etc.
Samples cupSupport one-off micro cups
Sample volume2-100 ul, step by 0.1 ul
Sample/reagent probeAutomatically checked ;Patent technology liquid level detection;Collision protection probe cleaning:Automatic washing for both inside and outside.
Temperature control Unit
Heating methodDirect thermal solid thermostat closed
Temperature equilibrium time<3 minutes
Reaction temperature37 ±0.1 degree
Temperature fluctuation±0.1 degree
Operation Unit
SoftwareWindowsXP \2000
DatabaseSQL Server
Data StorageAutomatic store & copy; No time and volume limit; Lifetime preservation
Print formatCan be set up, offer several standard format
Calibration modeLinear curve type: Single-point linear, two-point linear and multi-point linear none linear; Curve type: Logistic-Log 4P,Logistic-Log5p,Spline,index automatically use best calibration curve and standard
Quality control methods :Real time, within day & between day
Quality control diagramL-J \cumulative\twin plot
Status displayReal time monitoring of reagent residual volume .Running status of reagent tray, samples tray
AdjustmentDynamic and real time display of running status; Intelligent carry over settings to adjust test sequence; original reaction data record; Detail profile of alert messages         
SettingOperation permission setting, Item setting, cross pollution setting, cuvette blank setting
Water consumption : < 6L/hPower Supply :AC 220V±22V 50Hz±1Hz
Frequency :Maximum 600VADimension :782mm×581mm×545mm
Net Weight : 60kgAccessory :Software