Medical Equipment Hospital Spx-I Anaerobic Cultivation Incubator Non-Oxygen Incubator

Product Details
Customization: Available
Application: Industry, School, Hospital, Lab
Customized: Non-Customized
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Terms of Payment
LC, T/T, Western Union, Money Gram
OEM/ODM Availability
Yes
  • Medical Equipment Hospital Spx-I Anaerobic Cultivation Incubator Non-Oxygen Incubator
  • Medical Equipment Hospital Spx-I Anaerobic Cultivation Incubator Non-Oxygen Incubator
  • Medical Equipment Hospital Spx-I Anaerobic Cultivation Incubator Non-Oxygen Incubator
  • Medical Equipment Hospital Spx-I Anaerobic Cultivation Incubator Non-Oxygen Incubator
  • Medical Equipment Hospital Spx-I Anaerobic Cultivation Incubator Non-Oxygen Incubator
  • Medical Equipment Hospital Spx-I Anaerobic Cultivation Incubator Non-Oxygen Incubator
Find Similar Products

Basic Info.

Model NO.
SPX-I
Certification
CE, ISO, Non-Oxygen Incubator
Material
Stainless Steel
Type
Incubator
Power Supply
220V ±10% 50Hz
Oxygen-Eliminating Time in Sampling Room
< 5min
Oxygen-Eliminating Time in Operation Roo
< 1 H (Oxygen Concentration≤1%)
Non-Oxygen Maintaining Time
> 12 H (When No Supply of Mixed Gas in Operation R
Temperature Range in Incubation Room
Rt+3~60ºC
Sampling Room Path (Cm)
16×24.5
Temperature Fluctuation in Incubation RO
≤±0.3ºC
Power Supply/Consumption
220V, 50Hz/600W
Packing Dimensions (Cm)
134×88×159
Temperature Uniformity
≤±1ºC
Transport Package
Standard Export Wooden Case
Trademark
ysenmed
Origin
China
Production Capacity
500PCS/Month, Non-Oxygen Incubator

Product Description

Factory price anaerobic cultivation incubator  non-oxygen incubator
Model:  SPX-I
Medical Equipment Hospital Spx-I Anaerobic Cultivation Incubator Non-Oxygen Incubator

Specification:

This instrument is used for a non-oxygen environment to cultivate and handle anaerobic microbes. It can provide a strict anaerobic and constant temperature condition and a systematic and scientific working area. The most difficult microbe can be cultivated in this instrument and can avoid the death of culture caused by being exposed to the atmosphere during operation. This can be applied for medical institution in inspection and research of pathogenic anaerobic bacterium, microbiological examination brewing of food hygiene, and other hypoxia, microaerobic, or oxygen-free environment.
 
Structure features:
 ·This product is composed of constant temperature incubation chamber, anaerobic operation room, sampling room, gas and electricity control system, bottle holder and disinfector, etc. It's ingeniously designed to form a stable anaerobic environment in the operation room.
·Microprocessor intelligent temperature controller with over-temperature protection.
·UV lamp is equipped for gas disinfection.
·The gas flow can be adjusted for different inlet gas.
·Operation room is made of stainless steel and the front door is made of thick transparent shockproof special glass.
·Dedicated gloves for a comfortable and flexible operation.
·Operation room is equipped with special loop-carrier disinfector, experiment shelves, wax melting disinfector and oxygen eliminating catalyst.
·The gas flow can be adjusted for different inlet gas.
·Operation room is made of stainless steel andthe front door is made of thick transparent shockproof  special glass.
·Dedicated gloves for a comfortable, flexible operation.
·In the operation room it's equipped with melting disinfector, experiment shelves, and oxygen eliminating catalyst. 


Technical specifications of the incubator

 
Model YQX-I   
Sampling room path (cm) 16×24.5
Oxygen-eliminating time in sampling room < 5min
Oxygen-eliminating time in operation room < 1 h (Oxygen concentration≤1%)
Non-oxygen maintaining time > 12 h (when no supply of mixed gas in operation room)
Temperature range in incubation room RT+3~60ºC
Temperature fluctuation in incubation room ≤±0.3ºC
Temperature uniformity in incubation room ≤±1ºC
Power supply/Consumption 220V, 50Hz/600W
Size of incubation room (cm) 25×19×29
Size of operation room (cm) 81×65×66
Outline dimensions (cm) 121×74×141
Packing dimensions (cm) 134×88×159
 
 

Model:  YQX-II

Specification: 

This instrument is used for a non-oxygen environment to cultivate and handle anaerobic microbes. It can provide a strict anaerobic and constant temperature condition and a systematic and scientific working area. The most difficult microbe can be cultivated in this instrument and can avoid the death of culture caused by being exposed to the atmosphere during operation. This can be applied for medical institution in inspection and research of pathogenic anaerobic bacterium, microbiological examination brewing of food hygiene, and other hypoxia, microaerobic, or oxygen-free environment.
 
Structure features:
 ·This product is composed of constant temperature incubation chamber, anaerobic operation room, sampling room, gas and electricity control system, bottle holder and disinfector, etc. It's ingeniously designed to form a stable anaerobic environment in the operation room.
·Microprocessor intelligent temperature controller with over-temperature protection.
·UV lamp is equipped for gas disinfection.
·The gas flow can be adjusted for different inlet gas.
·Operation room is made of stainless steel and the front door is made of thick transparent shockproof special glass.
·Dedicated gloves for a comfortable and flexible operation.
·Operation room is equipped with special loop-carrier disinfector, experiment shelves, wax melting disinfector and oxygen eliminating catalyst.
·The gas flow can be adjusted for different inlet gas.
·Operation room is made of stainless steel andthe front door is made of thick transparent shockproof  special glass.
·Dedicated gloves for a comfortable, flexible operation.
·In the operation room it's equipped with melting disinfector, experiment shelves, and oxygen eliminating catalyst.
·Big LCD display temperature controller with timing and efficient temperature limit protection.
·Touch button for solenoid valve, which is easy to control the gas.
 

Technical specifications of the incubator
Model YQX-II YQX-II 
( Upgraded model)
Sampling room path (cm) 16×24.5 27.5×29.5
Oxygen-eliminating time in sampling room < 5min ≤ 15min
Oxygen-eliminating time in operation room < 1 h (Oxygen concentration≤1%) ≤ 2 h
Non-oxygen maintaining time > 12 h (when no supply of mixed gas in operation room)
Temperature range in incubation room RT+3~60ºC
Temperature fluctuation in incubation room ≤±0.3ºC
Temperature uniformity in incubation room ≤±1ºC
Power supply/Consumption 220V, 50Hz/600W
Size of incubation room (cm) 25×19×29 42×30×50
Size of operation room (cm) 81×65×66 95×75×68
Outline dimensions (cm) 121×74×141 140×73×137
Packing dimensions (cm) 134×88×159 154×87×155

Please let us know your specfic request. We would like to recommend you the most suitable model based on your information. 

Medical Equipment Hospital Spx-I Anaerobic Cultivation Incubator Non-Oxygen Incubator
Medical Equipment Hospital Spx-I Anaerobic Cultivation Incubator Non-Oxygen Incubator
Medical Equipment Hospital Spx-I Anaerobic Cultivation Incubator Non-Oxygen Incubator
Medical Equipment Hospital Spx-I Anaerobic Cultivation Incubator Non-Oxygen Incubator

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More