Ysenmed ® YSTE180C
Automatic Chemistry Analyzer |
Specifications |
Analyze Unit |
Throughput |
Constant 180T/h (non-ISE) |
Theory |
Absorption spectrometry, transmission turbidimetry |
Methodology |
End-point \Fixed-time\Kinetic\Ion selective electrode |
Test according set up, random access |
Reaction plate |
Contain 81 reaction cuvettes |
Maximum reaction time |
15 minutes |
Minimum reaction volume |
150 ul |
Material of cuvettes |
Special UV-transparent optical glass |
Cuvettes use |
Automatically cuvettes washing |
Optical Unit |
Light Source |
Halogen-tungsten lamp |
Photometer |
Reversed optics |
Wavelength |
340nm-900nm wavelength option |
Absorption |
0-4 Abs |
Reagent Unit |
Reagent plate |
60 reagent positions ,support for single and double reagent, reagent completely open |
Reagent storage temperature |
2~10 degree |
Reagent bottle |
15ml, 20ml, 30ml, 50ml or 70ml ,dead volume is less than 1.0 ml |
Reagent volume |
20-500 ul, step by 1.0 ul |
Reagent/Sample Probe |
Automatically checked ;Patent technology liquid level detection;Collision protection probe cleaning:Automatic washing for both inside and outside. |
Sample Unit |
Sample plate |
60 sample positions |
Sample type |
Human (animal) serum \plasma\urine etc. |
Samples cup |
Support one-off micro cups |
Sample volume |
2-100 ul, step by 0.1 ul |
Sample/reagent probe |
Automatically checked ;Patent technology liquid level detection;Collision protection probe cleaning:Automatic washing for both inside and outside. |
Temperature control Unit |
Heating method |
Direct thermal solid thermostat closed |
Temperature equilibrium time |
<3 minutes |
Reaction temperature |
37 ±0.1 degree |
Temperature fluctuation |
±0.1 degree |
|
Operation Unit |
Software |
WindowsXP \2000 |
Database |
SQL Server |
Data Storage |
Automatic store & copy; No time and volume limit; Lifetime preservation |
Print format |
Can be set up, offer several standard format |
Calibration mode |
Linear curve type: Single-point linear, two-point linear and multi-point linear none linear; Curve type: Logistic-Log 4P,Logistic-Log5p,Spline,index automatically use best calibration curve and standard |
Quality control methods : |
Real time, within day & between day |
Quality control diagram |
L-J \cumulative\twin plot |
Status display |
Real time monitoring of reagent residual volume .Running status of reagent tray, samples tray |
Adjustment |
Dynamic and real time display of running status; Intelligent carry over settings to adjust test sequence; original reaction data record; Detail profile of alert messages |
Setting |
Operation permission setting, Item setting, cross pollution setting, cuvette blank setting |
Others |
Water consumption : < 6L/h |
Power Supply :AC 220V±22V 50Hz±1Hz |
Frequency :Maximum 600VA |
Dimension :782mm×581mm×545mm |
Net Weight : 60kg |
Accessory :Software |