Main body | High-strength engineering plastic rack, light, beautiful and corrosion resistant |
||
Scope of application | adult, child | ||
Gas source | O2: 0.27-0.55MPa N2O: 0.27-0.55MPa | ||
Flow meter | O2: 0.1-10L/min N2O: 0.1-10L/min | ||
O2, N2O linkage and N2O Stopper When using nitrous oxide, oxygen concentration>25%; When the oxygen pressure<0.2MPa, the flow of nitrous oxide would be cut off. |
|||
Flow rate of rapid oxygen supply | 25-75L/min | ||
Low oxygen pressure alarm | There will be sound alarm when the oxygen pressure < 0.2MPa |
||
Vaporizer | it has the function of automatic compensation based on pressure, temperature, and flow rate. The regulation range of evaporator concentration is 0-5 vol%. Among Halothane, Enflurane, Isoflurane and Sevoflurane, one can be chosen for application as required by the customer. And vaporizers that are imported with original packaging are also available. |
||
Respiratory circuit | working mode: all-close, semi-close, semi-open releasing pressure: 0.5-7 kPa |
||
Respiratory bellows | bellows for adults, bellows for children tidal volume range:0-1,500 ml |
||
Ventilator | |||
Display mode | High-definition 5.7" LCD screen display | ||
Ventilation mode | IPPV,SIPPV,SIMV,PEE,MANUAL,SIGH | ||
Ventilation parameters | Tidal volume | 50-1500ml | |
Rate | 2-99bmp | ||
SIMV rate | 2-20bpm | ||
I:E | 2:1-1:8 | ||
Inspiratory trigger pressure | -1.0-2.0 kPa | ||
PEEP | 0-2.0 kPa | ||
Pressure range | 1.0-6.0 kPa | ||
SIGH | 1.5 times the inspiratory time | ||
Parameters for ventilation monitoring tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure |
|||
Monitoring of oxygen concentration | (21%-100%) | ||
Security Alarm System | |||
Oxygen Concentration alarm | upper limit setting range (50%-100%) | ||
low limit setting range (15%-50%) | |||
Airway pressure alarm | upper limit setting range 1.0-6.0 kPa | ||
low limit setting range 0.4-2.0 kPa | |||
Per-minute ventilation volume alarm | upper limit setting range 3.0-30L/min | ||
low limit setting range 1.0-10L/min | |||
Sustained high-pressure alarm | it will give alarm when stress have consistently been higher than 2.5 kPa |
||
Suffocation alarm | it will give sound and light alarm if there is no tidal volume input for 15 seconds |
||
Power alarm | |||
Power | AC 220V±10% 50Hz±1Hz (UPS, Storage battery) |
||
Items within brackets are optional. |
one-stop shopping for operation room | anesthesia machine |
ventilator | |
operating lamp | |
operation table | |
Pendant | |
medical drill and saw | |
ECG | |
patient monitor | |
Defibrillator | |
infusion pump | |
Electrocoagulation | |
oxygen generator | |
electric suction device | |
autoclave sterilizer |