Customization: | Available |
---|---|
Classification: | Imaging Diagnostic Equipment |
Type: | X Ray Equipment |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Main components | Technique parameter | ||||
IMD X-ray tube | Model:YSX-C35D | Model:YSX-C50D | |||
Power:3.5kW | Power:5.0kW | ||||
Double focus fixed anode focus:1.5mm / 0.6mm | Double focus rotational anode focus: 0.3mm / 0.6mm | ||||
Anode Heat Capacity:40kHu X-ray tube sleeve heat capacity:667kHu | Anode Heat Capacity:200kHu X-ray tube sleeve heat capacity:800kHu | ||||
High Voltage X-ray Generator | Working frequency:40kHz | ||||
Image intensifier | 9"(including 3 fields of view 4.5"/ 6"/9") | ||||
Tube voltage | Fluoroscopy Radiograph:40kV-110kV | Fluoroscopy Radiograph:40kV-120kV | |||
Tube current | Fluoroscopy: 0.5-4mA Enhanced Automatic Fluoroscopy: 1mA-8mA Pulse Fluoroscopy :2pps;8mA | ||||
mAs | 1mA.s-250mA.S | ||||
Fluoroscopy mode | Manual Fluoroscopy; Semi-Automatic Fluoroscopy;Automatic Fluoroscopy; Enhanced Automatic Fluoroscopy; Pulse Fluoroscopy | ||||
Intelligent exposure control | No matter the object is in the center or on the fringing field of the image intensifier, the images are the same. The exposure dose is reduced. | ||||
Iris beam limiting device | when not exposure, keep in the state of Iris Beam limiting preview ,when exposure,keep blanking cycle track | ||||
General radiography | 40kV-120kV;1.0mA.s-250mA.s | step length 1 kV;1.0mA.s | |||
Digital radiography (digital spot film) | 40kV-120kV;Max 16mA | Common screen film radiography is eliminated. Digital radiography can get better images | |||
C-arm machinery index | C-arm stander(with perfect C arm balance system) of ultra-quiet motor-driven up and down, easy and handy to operate. The machine can maintain balance with up and down of the C arm. | ||||
Distance between focus and window>900mm, arc depth>650mm, horizontal moving range :200mm vertical moving range:400mm | |||||
Tilt angle :±12.5° rotation :±180°corner:125°(-35°-- +90°) | |||||
Laser Orientation | Laser positioning function can help to position precisely and reduce exposure times in the operation, reduce unnecessary radiation. | ||||
Radiography mode | |||||
Image intensifier & Real-time digital image(1.3 million pixel) processing system | |||||
(CCD)Digital video camera | million pixels high-definition, high-speed CCD camera, a 1024 × 1024 matrix, 30 frames per second image acquisition, through real-time adjustment of window width, window level, noise reduction, sharpening and Gain adjustment to ensure high-quality and high-resolution images. | ||||
Image resolution index | Grey level:10 Resolution:22 lp/cm | ||||
Camera virtual rotation design | No X-ray needed, also called digital image rotation,display the right angle when exposure, superior to camera mechanical rotation | ||||
Image processing system | 1.Real time edge enhancement(sharpening) | Image sharpening is also called edge enhancement, that is, to make blurry edge of the image clearer | |||
2.Real time adjustment of the window width and window level | Obtain images by real-time adjustment of window width,window level, displaying images with different brightness. | ||||
3.Real time(static)multiform noise reduction | Noise reduction, and improve image clarity | ||||
4.Real tim GAIN adjustment | Can amplify image signal, reduce x-ray dose, suitable for patient with super large size. | ||||
5.Real tim dynamic brightness compensation and R calibration functions | Through dynamic logarithmic transformation,linear reduction the system signals and r calibration technology, dark parts of the image can be enhanced and clear rich-layer images can be obtained | ||||
6.Image conversing ,up-down and right-left rotating,and frame freezing | |||||
7.Patient information management ,Clinic report and print | |||||
8.The Image can be storage as JPG and DICOM 3.0 format, can be linked to hard-disk ,USB and DVD and printer,meet the need of sharing the network information ,communication and storage in hospital | |||||
Display | Display2 17' TFT-LCD display | ||||
Printer | Printer Laser / jet Printer | ||||
Standard configuration | 1.Combined tube(5.0kW)IMD | 1 set; | |||
2.Image intensifier (9 inch 3 fields of view) | 1 set | ||||
3.C-arm stander (with full C-arm balance system) | 1 set; | ||||
4.Exported grid | 1 set | ||||
5.Laser positioning | 1 set; | ||||
6.1.3million pixel 1024×1280×10bit camera | 1 set; | ||||
7.Electric adjustable beam limiting device | 1 set | ||||
8.17 inch LCD high resolution screen | 2 sets | ||||
9.Real-time digital imageprocession system (station) | 1 set; | ||||
10.Printer | 1 set |
One-stop shopping Hospital medical equipment |
X ray room | X ray machine |
Processor | ||
X ray film | ||
Cassette | ||
Intensifying screen | ||
Lead clothings(lead glove, lead glasses, Lead cap, lead apron, lead collar) |
||
Ultrasound | B/w 2D ultrasound | |
2/3/4D color ultrasound | ||
Laboratory room | Chemistry analyzer | |
Hematology analyzer | ||
Microplate elisa reader | ||
Microplate washer | ||
Centrifuge | ||
Pipette | ||
Water bath | ||
Urine analyzer | ||
Operation room | Anesthesia machine | |
Ventilator | ||
Operating lamp | ||
Operation table | ||
Pendant | ||
Medical drill and saw | ||
ECG | ||
Patient monitor | ||
Defibrillator | ||
Infusion pump | ||
Electrocoagulation | ||
Oxygen generator | ||
Electric suction device | ||
Autoclave sterilizer |