Customization: | Available |
---|---|
Respiration Frequency: | 1~99bpm |
4-Tube Flowmeters: | O2 & N2o;0.1 L/Min ~ 10 L/Min |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Specification |
|
Pneumatically driven electronically controlled system |
|
Built-in ventilator, 5.4" LCD display screen |
|
With 1 patient circuit for adult (Option: patient circuit for children). |
|
4-tube flowmeters, O2 & N2O ;0.1 L/Min ~ 10 L/Min; |
|
One vaporizer: |
|
Oxygen Flush: |
25~75 L/Min; |
Respiration Mode: |
IPPV, SIPPV(VCV), IMV, SIMV, PEEP, Manu, Sigh |
Tidal Volume: |
0~1500 mL; |
I:E: |
4:1, 3:1, 2:1, 1:1, 1:1.5, 1:2.0, 1:2.5, 1:3, 1:4; |
Respiration Frequency: |
1~99bpm; |
PEEP: |
1~10 hPa; |
Ptr: |
-10~10 hPa; |
CO2 absorber capacity: |
1 kg |
Lung compliance: |
≤ 30 mL/kPa; |
IMV frequency: |
1~12bpm |
Inspiratory Plateau: |
0~1S; |
Alarm parameter: |
upper /lower limit of airway pressure, tidal volume exceed limitation, no tidal volume output, apnea, AC power malfunction, battery low power |
hospital anesthesia equipment
Model:YSAV01A2
Anesthesia host:
1. Flowmeters:4-tube flowmeters, O2 & N2O;0.1 L/Min ~ 10 L/Min;
2. Oxygen Flush:25~75 L/Min
3. Air pressure:O2:0.3~0.5MPa,N2O:0.3~0.5MPa
Anesthesia ventilator:
1. Respiration Mode:IPPV, SIPPV, Manu
2.Tidal Volume:50~1500 mL;
3. Respiration Frequency:4~40 bpm
4. I:E:1:1.5~1:3.0
5. Ptr:-10~10 hPa;
6. Max safety pressure:≤125hkPa
7. Monitoring parameter:tidal volume,respiration mode,I:E and so on.
8. Alarm parameter: upper/lower limit of ventilation volume, upper /lower limit of airway pressure,
tidal volume exceed limitation, no tidal volume output, apnea, AC power malfunction, battery low power
Configuration:
1. Vaporizer:Two vaporizer
2. Anesthetic gas concentration range:0.5~5%
3. Soda lime absorption system,resistance to high temperature of 150 degrees Celsius.
4. Through the CE certification.
medical anesthesia equipment
Model:YSAV01A1
Pneumatically driven electronically controlled system
Built-in ventilator, LED display screen
With 1 patient circuit for adult (Option: patient circuit for children).
4-tube flowmeters, O2 & N2O;0.1 L/Min ~ 10 L/Min;
One vaporizer
Oxygen Flush: 25~75 L/Min;
Respiration Mode: IPPV, SIPPV, Manu
Tidal Volume: 50~1500 mL;
I:E: 1:1.5; 1:2.0; 1:2.5; 1:3
Respiration Frequency: 4~40 bpm
Ptr: -10~10 hPa;
CO2 absorber capacity: 1.5 kg
Alarm parameter: upper/lower limit of ventilation volume, upper /lower limit of airway pressure, tidal volume exceed limitation, no tidal volume output, apnea, AC power malfunction, battery low power
operation room | anesthesia machine |
ventilator | |
operating lamp | |
operation table | |
Pendant | |
medical drill and saw | |
ECG | |
patient monitor | |
Defibrillator | |
infusion pump | |
Electrocoagulation | |
oxygen generator | |
electric suction device | |
autoclave sterilizer |