Assay Model: Random Access with Direct Reading Sys
Assay Item: 40 Assay
1 Reagent: 240 Test/H(Max)
2 Reagent: 150 Test/H
with ISE: +120 Test/H
Sample Position: 60
Customization:
Diamond Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
YSTE261
Sample Volume
40 or 80(Optional)
Reagent Volume
R1:1-400UL,1UL/Step,R2: 1-400UL,1UL/Step
Wavetength
340-810nm
Light Source
Halogen Lamp
Transport Package
Carton
Trademark
YSENMED
Origin
China
Production Capacity
50000 PCS/Year

Product Description

Medical cheap fully auto laboratory chemistry analyzer
YSTE261


Yste261 Medical Cheap Fully Auto Laboratory Chemistry Analyzer


Technical Specificaions:
Assay Model: Random access with direct reading system
Assay Item: 40 assay
Throughput: 1Reagent:240 test/h(max); 2 Reagent: 150 test/h; With ISE: +120 test/h    
Sample Position: 60
Sample Volume: 1-100ul,0.1ul/step
Reagent Position:40 or 80(optional)
Reagent Volume: R1:1-400ul,1ul/step,R2: 1-400ul,1ul/step
Wavetength: 340-810nm
Light Source: Halogen lamp
Method: End point, Kinetic, Fixed time, Immunoturbidimetry, 1-2 reagent,Multistandard, reagent/serum blank, etc
Quality Control: Levy Jennings quality control program at 3 levels.

Printer: Multiple report formats available         


Application:

Biochemistry Analyzer is designed for hospital or clinical laboratory to measure the quantity of chemical or biochemical components in human serum, urine and other liquid sample, used to test liver function, kidney function, cardiac markers, blood sugar, blood lipid, etc.

Technical Specifications
Model YSTE261
Analytical System Fully automatic, Random Access, Discrete
Method End point, Rate, Fixed time, Immunoturbidimetric, 1-2 regent, Multistandard, reagent/serum blank, etc
Assay Item 40 assay
ISE mould(K+, Na+, Cl-, Ca2+) available on request
Throughput 1 Reagent 240 tests/hr
2 Reagent 150 tests/hr
With ISE 120 tests/hr
Test Menu T.BILI         r-GT/GGT    CHO    Ca      APOB-1/B   CHE
D.BILI        ALP/AKP     TG      CL      APOB       CREA
TP           UREA        CK      P       CK-MB      Mg
ALB          CREA        LDH    C        ASO        AFU
Lactic Acid    ALT/GPT      UA    α-HBDH  CO2        FMN
LP(a)         AST/GOT     GLU   AMY      LDL-C      HDL-C
CHE          LA           TBA    ADA      HS-CRP    PA
Fe            Cu           Zn     C3       C4          IgG
IgM           IgA           and drug, toxicity,etc.
Sample Position 60
Including standard, control and STAT; either serum cup or primary tube available
Sample Volume 1~100ul, 0.1ul/step
Reagent Position 40
Reagent Volume R1: 1~400ul, 0.1ul/step, R2: 1~400ul, 0.1ul/step
Reagent/Sample Probe With liquid level sensor, collision sensor, coating and automatic washing station
Reaction Time 0~999 seconds
Cuvette High quality uv-transmitted plastic cuvette.
Cuvette Washing 8 channels automatic washing system for reaction cuvettes
Probe and Mixer Washing Independent washing station for each sample/reagent probe and mixer
Alarm Automatic alarm for malfunction (eg: collision, reagent/sample insufficiency, full waste container, etc)
Calibration Linear, Non-linear, Multi standard, K factor
Sample Dilution/Retest Sample can be diluted and retested if results are out of range or sample is insufficient. Also with calibrator auto diluting function
Wavelength 340-810nm
Light Source Halogen lamp
Absorbance Resolution 0.0001A
Absorbance Accuracy ±0.0003A(0-2.5A)
Repeatability ±2%
Quality Control Levy jennings quality control program at 3 levels
Barcode Optional
Printer Multiple report formats available
System Windows XP; Windows 7
Power Supply 220V or 110V, 50~60Hz
Dimension 85×72×53(cm)
Weight 85kg


Features:
 
  1. Random access fully automatic biochemistry analyzer
  2. New concept and more friendly software
  3. Automatic washing station for both sample and reagent probe
  4. Liquid level detection and collision protection for both sample and reagent probe
  5. Reliable cooling system for reagent chamber, condensate cooling design and peltier cooling system double ensure the cooling effect.
  6. Powerful reaction cuvette washing system
  7. ISE Unit & barcode scanner (optional)
  8. Lower waste and pro-environment

Structure:
1. Optical System
Light source: Halogen-tungsten lamp, 2000hours working life about
Wavelength: 340nm-810nm
Linear range:0~3ABS
2. Sample System
  1. Sample tray: 60 sample position, available to use serum cup or blood tube
  2. Sample volume:1~100ul, programmed by 0.1ul step
  3. Sample probe: Liquid level detection and collision protection automatically
  4. Probe cleaning: automatic washing both inside and outside, Carryover<0.1%
  5. Automatic sample dilution
3. Reagent System
  1. Reagent tray: 40 positions for single &dual Reagents.
  2. Refrigeration: Refrigerated reagent
  3. Compartment 24h Cooling system maintaining temperature 2~8°C
  4. Reagent volume:1~400ul, programmed by 0.1ul step
  5. Reagent probe: Liquid level detection and collision protection automatically
  6. Pre-heating function.
  7. Real-time monitoring of reagent volume and auto alarm
  8. Probe cleaning: automatic washing both inside and outside, Carry over<0.1%
4. Reaction System
  1. Reaction tray: 90 reaction cuvettes, High quality UV-transmitted plastic cuvettes adopt, flat design to ensure heating evenly
  2. Back-Dividing-Light technology
  3. Min Reaction volume: 180ul
  4. Reaction Temperature:37°C+0.1°C
  5. Mixing system: Independent mixing probe
  6. Automatic washing cuvettes
5. Washing System
  1. Automatic cleaning Sample/mixer probe
  2. Five channels washing station for each cuvette
  3. Automatic record and deduct cuvette blank value
6. Operation Unit
Operation system: Windows XP or WIN 7
Interface: RS-232
7. Working Conditions
  1. Power Supply: 220V±10%, 50/60HZ; 110V (optional)
  2. Power consumption: ≤1200VA
  3. Temperature:15~30°C
  4. Humidity: ≤85%
  5. Water consumption: 6L/h

Yste261 Medical Cheap Fully Auto Laboratory Chemistry Analyzer

Yste261 Medical Cheap Fully Auto Laboratory Chemistry Analyzer

Yste261 Medical Cheap Fully Auto Laboratory Chemistry Analyzer

Yste261 Medical Cheap Fully Auto Laboratory Chemistry Analyzer
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now