Customization: | Available |
---|---|
Type: | CT |
Certification: | CE, ISO13485 |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
No. | Part name | Model | Specifications | Remarks |
1 | Scanning frame | SM100 | Scanning frame aperture: 700mm±10mm Scanning frame rotation speed: 0.75s, 1.0s, 1.5s, 2.0s Scanning field of view: 430mm Type of Slip ring: contact slip ring |
|
2 | High voltage generator | CT70PN32X5610 | Tube voltage setting: 70~140kV Tube current range: 10~300mA Nominal output power: 32kW |
|
3 | Collimator | CMT-003 | Half value layer:≥4.6mmAl Equivalent aluminum equivalent thickness:2.3mmAl |
|
4 | X-ray tube sleeve | B-240H | Nominal tube voltage: 140kV Nominal anode input power: 29kW/48kW Maximum continuous heat dissipation of anode: 3.5kW Focus size: 0.7mm ×0.8mm 1.2mm ×1.4mm Anode rotation speed: 60Hz/180Hz Diameter of anode target surface (mm): 140mm Target angle: 7° Anode type: rotating anode Bearing type: mechanical bearing Quantity (pcs): 1 Fly focus (x to z offset): none The longest spiral scanning time: 100s Anode heat capacity:2MHU |
|
X-ray tube | GS-30722 | |||
5 | Detector | DET-003 | Scintillation crystal material: GOS crystal Pixel matrix: 704×16 Number of detectors: 11 Coverage (projected to the center of rotation): 430mm Pixel size (projected to the center of rotation) 1.25mm × 1.25mm Scanning angle: 0°/90° Scanning field of view: 430mm Axial scanning layer thickness: 1.25 mm ± 0.625 mm, 2.50 mm ± 1.0 mm, 5.00 mm ± 1.0 mm, 10.0 mm ± 1.0 mm; Spiral scanning layer thickness: 1.25 mm ± 0.625 mm, 2.50 mm ± 1.0 mm, 3.75 mm ± 1.0 mm, 5.00 mm ± 1.0 mm, 7.50 mm ± 1.0 mm, 10.0 mm ± 1.0 mm; Collimation combination: 16×1.25, 4×1.25; |
|
6 | Diagnostic bed | ZC300 | Z-axis positioning accuracy (mm): ≤±1mm Speed: 0~150mm/s Vertical lifting range: ≥440mm Maximum load: 205kg |
|
7 | Laser | M63AXSAXX-XX | Category: 2 types Positioning accuracy: ±1mm Wavelength: 600~700nm Maximum output power: <1mW |
|
8 | Console CZ100 |
KH100 | Control box: Exposure control Bed motion control Intercom function |
|
/ | Computer The minimum configuration requirements are as follows CPU performance: the main frequency is not less than 2 GHz, the number of cores is not less than 2 cores Memory size: no less than 8GB Image storage capacity: no less than 850GB |
Should have CCC certificate, should comply with GB4943.1, GB9254, GB17625.1 standard |
||
/ | Monitor The minimum configuration requirements are as follows Screen resolution: 1920×1200 SXGA Number of displays size: 1*24 inches Type: LCD, color Contrast ratio: 1000:1 Preview |
|||
9 | Computer image processing software | ScintVue | Release version: 1.0 | |
System parameters | ||||
The X-ray source assembly rotates 360°, and the maximum number of scan layers that can be obtained in a single axial scan is 32. Maximum scanning range: 1200mm Pitch coefficient: 0.25, 0.5, 0.75, 1, 1.25, 1.5, 1.75 Scan mode: positioning scan, tomographic scan, spiral scan, enhanced scan, perfusion scan |
||||
Software function | ||||
Patient file management Patient registration Scan function reconstruction 2D image browsing and processing 3D image browsing and processing Film printing Data management function |
||||
Annex |