Ysx200g 20kw/200mA High Frequency Medical X Ray Machine Digital X Ray

Product Details
Customization: Available
Classification: Imaging Diagnostic Equipment
Type: X Ray Equipment
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Terms of Payment
LC, T/T, Western Union, Money Gram
OEM/ODM Availability
Yes
  • Ysx200g 20kw/200mA High Frequency Medical X Ray Machine Digital X Ray
  • Ysx200g 20kw/200mA High Frequency Medical X Ray Machine Digital X Ray
  • Ysx200g 20kw/200mA High Frequency Medical X Ray Machine Digital X Ray
  • Ysx200g 20kw/200mA High Frequency Medical X Ray Machine Digital X Ray
  • Ysx200g 20kw/200mA High Frequency Medical X Ray Machine Digital X Ray
  • Ysx200g 20kw/200mA High Frequency Medical X Ray Machine Digital X Ray
Find Similar Products

Basic Info.

Model NO.
YSX200G
Certification
ISO13485
Group
All
Intermittent Mode
100kv ,200mA,20kw
Power Voltage
380V±10% 50Hz±10%
Tube Current
Radiographyt16mA~200mA
Output Voltage
Radiography 40-125kvtstep 1kv;
Output Power
20kw
Resistance Power
Less Thant0.5
Nominal Frequency
30kHz
Exposure Time
Radiography 0.0025s~6.4s Adjustable
Speed of Anode Rotating
2800r/Min
Anode Heat Capacity
140khu
Transport Package
Carton
Specification
20kW high frequency radiography x-ray machine
Trademark
YSENMED
Origin
Guangzhou
HS Code
9022199090
Production Capacity
500 Sets/Year

Product Description

YSX200G 20kw/200mA High Frequency Medical X Ray Machine Digital X ray
YSX200G
Ysx200g 20kw/200mA High Frequency Medical X Ray Machine Digital X Ray


Features:
1. High precision control mode through analog & digital double-loop control: Adopting HF (≥ 30kHz)inverter circuit combined with analog & digital double-loop control mode (composed of microprocessor and PWM dedicated chip), in order to achieve high-precision high voltage output. Though power supply fluctuation may appear, steady x-rays can still be output.

2. High-precision control in radiography time: Minimum exposure time is 0.0025 second, and quick radiography is accessible at any time without the influence of power phase, thus high-quality X-ray films are easily achieved and X-ray radiation to patients is reduced.

3. High-precision tube current control: X-ray tube current using two high-frequency converter heating which is controlled by the microprocessor high-speed A / D converter sampling tube current calculate in real-time. The microprocessor control the allow load of the X-ray tube. It can be set out photographic conditions of expressing an effective X-ray tube capacity;

Technical index of main component:

Function: Radiography, single-table single tube
1. Maximum output power
Intermittent mode: 100kV, 200mA, 20kW.
2. Adjustment range of tube current\tube voltage
Tube current: Radiography 16mA~200mA.
Tube voltage: Radiography 40kV~125 kV.
3. Exposure Time: Photography0.0025s~6.4s step adjustable
4. Frequency operation≥ 30kHz
5. The condition of power
Power Voltage: 380V± 10%
Power supply capacity: 120% the power of the equipment
Internal resistance: ≤ 0.5.

6. High frequency and high voltage X-ray generator(including microcomputer control console)
Frequency operation of high voltage X-ray generator≥ 30kHz.
Internal resistance: Less than 0.5.
Output power: 20kW.
Output Voltage: Radiography: 40 kV~125kV, step 1kV;
Output Current: Radiography: 16mA~200mA,
Exposure Time: 0.0025s~6.4s.
Display: Digital pipe display photography voltage\ Photography current\ photography time\ mAS of photography
X-ray tube
Max tube voltage: 125kV Max tube current: 400mA.
Small focus: 1.0mm; Big focus: 2.0mm.
Speed of anode rotating: 2800r/min
Anode heat capacity: 140KHU
7. Collimator
Collimator with fixed position lamp.
Power supply: Working voltage: 24V
8. Radiography Bed
Integration of the bed with stand column without skyrail design.
Length*width*height of bed surface: 2000mm× 760mm× 690mm. Deviation: ± 10mm
Distance from table surface to film: 50mm
Horizontal movement distance of table≥ 220mm
Vertical movement distance of table≥ 900mm Way of locking: Manually single automatic multi-optional
9. X-ray source component pillar:
With the scaleplate indicating the height of X-ray tube source component pillar.
Distance of vertical movement: 770mm± 10mm; +90° ~-90° , deviation<± 2°
Moving crosswise (left & right): +180° ~-180° , deviation<± 2°
Moving lengthways (along ground railway) ≥ 1300mm
10. Ray-filter of table: Fixed beam filtration grid density≥ 40 lines/cm.
Ray-filter grid: Grid ratio 10: 1, . Focus Distance: 110cm

11. Horizontal movement of bucky ≥ 500
Braking Force of electromagnetic≥ 98N, Button operation.
12. Limited beam splitter start and closedown should portable, flexible, reliable, can adjust to any Radiation field rectangle size.
13. Fixed beam filtration grid density≥ 40 lines/cm.
Ray-filter grid: Grid ratio 10: 1, Focus Distance: 110cm
Cassette size: 53× 73 83× 103 103× 123 113× 143 143× 173
Product Configuration:
X-ray tube, 1 set
Radiography Table, 1 set
Collimator, 1 set
High-voltage generator, 1 set
Micro console, 1 set
High-voltage cable, 2 pieces
Vertical bucky stand (Optional), 1 set
CONTENTS YSX200G YSX500G
 
Intermittent mode
 
100kV ,200mA,20kW
 
100kV ,500mA,50kW
Power Voltage 380V±10% 50Hz±10%
tube current Radiography16mA~200mA Radiography32mA~630mA
Output Voltage Radiography 40-125KVstep 1kV;
resistance power less than0.5
Output power 20kW 50kw
 
Exposure Time Radiography 0.0025s~6.4s adjustable Radiography3ms~6sadjustable
Nominal Frequency 30kHz
Speed of anode rotating 2800r/min
Anode heat capacity 140KHU 150KHU
Focus Small focus:1.0mmBig focus:2.0mm
 
Length*width*height of bed surface
 
2000mm×750mm×690mmDeviation:±10mm
Horizontal movement distance of table ≥200mm
Vertical movement distance of table ≥900mm
Distance from table surface to film 50mm±2mm
Distance of vertical movement 770mm±10mm; 800mm-1100mm
Moving crosswise (left & right) +180°~-180°deviation<±2°
 
Moving lengthways (along ground railway)
 
≥1300mm
 
600mm
Fixed beam filtration grid density ≥40 lines/cm.
grid ratio 10:01
Focus Distance 100cm
 
Cassette size
 
5″×7″ 8″×10″ 10″×12″ 11″×14″ 14″×17″

 

Ysx200g 20kw/200mA High Frequency Medical X Ray Machine Digital X Ray
Ysx200g 20kw/200mA High Frequency Medical X Ray Machine Digital X Ray
Ysx200g 20kw/200mA High Frequency Medical X Ray Machine Digital X Ray
Ysx200g 20kw/200mA High Frequency Medical X Ray Machine Digital X Ray

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More