Medical Equipment Ysmri-042 Ysenmed 0.42t MRI System MRI Machine

Product Details
Customization: Available
Classification: Imaging Diagnostic Equipment
Type: X Ray Equipment
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Terms of Payment
LC, T/T, Western Union, Money Gram
OEM/ODM Availability
Yes
  • Medical Equipment Ysmri-042 Ysenmed 0.42t MRI System MRI Machine
  • Medical Equipment Ysmri-042 Ysenmed 0.42t MRI System MRI Machine
  • Medical Equipment Ysmri-042 Ysenmed 0.42t MRI System MRI Machine
  • Medical Equipment Ysmri-042 Ysenmed 0.42t MRI System MRI Machine
  • Medical Equipment Ysmri-042 Ysenmed 0.42t MRI System MRI Machine
  • Medical Equipment Ysmri-042 Ysenmed 0.42t MRI System MRI Machine
Find Similar Products

Basic Info.

Model NO.
YSMRI-042
Certification
CE, ISO13485, MRI System
Magnet Type
Permanent Magnet with Automatic Constant Temperatu
Homogeneity (40cm, Dsv, Vrms)
2ppm
Gradient Field Strength (Single Axis)
31mt/M
Gradient Slew Rate (Single Axis)
107mt/M/Ms
Rise Time
0.29ms
Transmitter Amplifier Peak Power
6kw
Transport Package
Carton of MRI System
Specification
CE ISO certificate
Trademark
ysenmed
Origin
China
Production Capacity
100set/Month, MRI

Product Description

YSMRI-042 YSENMED 0.42T MRI System

Medical Equipment Ysmri-042 Ysenmed 0.42t MRI System MRI Machine

No.
Item Specification
1 Magnet System  
1.1 Magnet Type Permanent magnet with automatic constant temperature system
1.2 Field strength 0.42T
1.3 Magnet shape C-shape
1.4 Homogeneity (40cm, DSV, VRMS) 2ppm
1.5 Shim method Active/Passive/Dynamic
1.6 Magnet vertical gap 40cm
1.7 Accessibility (Horizontal opening angle) 250°
1.8 5 Gauss fringe field 2.5m*2.5m*2.5m
2 Gradient System  
2.1 Gradient field strength (Single Axis) 31mT/m
2.2 Gradient slew rate (Single Axis) 107mT/m/ms
2.3 Rise time 0.29ms
2.4 Gradient cooling system(Gradient coils and power electronics) Air
3 RF System  
3.1 Spectrometer Fully digital
3.2 RF system type Digital Transmit and Receive
3.3 Number of RF channel 4
3.4 Transmitter amplifier peak power 6kW
3.5 RF bandwidth of receiver Each 400KHz
3.6 Dynamic range 80dB
3.7 Noise factor 0.3dB
3.8 Coil type phase array
3.9 Head coil Yes
3.10 Neck coil Yes
3.11 Body coil (small) Yes
3.12 Body coil (large) Yes
3.13 Knee coil Yes
3.14 Ankle coil Yes
3.15 Shoulder coil Optional
3.16 Soft coil Optional
4 Patient communication  
4.1 Max. patient weight 210Kg
4.2 High accurate position assist Yes
4.3 Localizer Yes
4.4 Position accurate 1mm
4.5 Position accessories Yes
4.6 Emergence call Yes
4.7 Communication system Yes
5 Computer system  
5.1 Host computer Dual core
Industrial computer
5.2 MRI software V30
5.3 OS WINDOWS 7
5.4 CPU clock rate 3.0GHz
5.5 Main memory 4GB
5.6 Color LCD monitor 24"
5.7 Keyboard and mouse Yes
5.8 Hard disk 500GB
5.9 Media driver CRW / DVD
5.10 DICOM 3.0 Yes
5.11 Ethernet Yes
6 Scanning parameter  
6.1 Max. FOV 400mm
6.2 Min. FOV 10mm
6.3 Min. 2D Thickness 1mm
6.4 Min. 3D thickness 0.1mm
6.5 Max. Image matrix 1024*1024
7 Scanning sequence &imaging technology  
7.1 Spin echo 2D/3D (SE 2D/3D) Yes
7.2 Multi-slice multi-echo(MSME) Yes
7.3 Gradient echo(GRE 2D/3D) Yes
7.4 Steady state process gradient echo( SSPGRE) Yes
7.5 Fast spin echo (FSE) Yes
7.6 Fast double echo(FDE) Yes
7.7 Fast recover fast spin echo(FRFSE) Yes
7.8 Single shot fast spin echo(SSFSE) Yes
7.9 Multi shot fast spin echo (MSFSE) Yes
7.10 Inversion recovery (IR) Yes
7.11 Inversion recovery fast spin echo (IRFSE) Yes
7.12 Short time inversion recovery (STIR) Yes
7.13 Fluid attenuated inversion recovery (FLAIR) Yes
7.14 Gating technology Yes
7.15 Breath holding scan Yes
7.16 TOF 2D MRA Yes
7.17 TOF 3D MRA Yes
7.18 Diffusion weighted imaging (DWI) Yes
7.19 Max. b Value 1000s/mm2
7.20 Magnetization transfer (MTC) technology Yes
7.21 MIP Yes
7.22 MinIP Yes
7.23 3D position scan Yes
7.24 Pre-saturation technology (PS) Yes
7.25 Pre-saturation adjustment technology Yes
7.26 Part metal implant scan technology Yes
7.27 Automatic coil tuning Yes
7.28 MRM Yes
7.29 MRU Yes
7.30 MRCP Yes
7.31 Online image filtration Yes
7.32 Online post procession Yes
7.33 Optimal algorithm of active shimming, must be available to check the shimming data at any time Yes
7.34 Scan sequence queuing Yes
7.35 Multi-layer and multi-angle scanning technology Yes
7.36 Optimize bandwidth acquisition technology Yes
7.37 Flow compensation Yes
7.38 Parallel acquisition technology Yes
7.39 Section acquisition technology Yes
7.40 Scan parameter preset Yes
7.41 Oversampling technology Yes
7.42 Image fusion technology Yes
7.43 Artifact suppression technology Yes
7.44 Thin imaging technology Yes
7.45 Movie playback technology Yes
7.46 Post processing package Yes

Medical Equipment Ysmri-042 Ysenmed 0.42t MRI System MRI Machine
Medical Equipment Ysmri-042 Ysenmed 0.42t MRI System MRI Machine
Medical Equipment Ysmri-042 Ysenmed 0.42t MRI System MRI Machine
Medical Equipment Ysmri-042 Ysenmed 0.42t MRI System MRI Machine

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More