Ysav-5b-M2 CPAP Infant Respirator Mobile Infant Bubble CPAP System with Air Compressor

Ventilation Mode: Newborn Babies CPAP
Flow: 0~18lpm
Certificate: Ce, ISO
Power Supply: AC220V/110V
Noise: <55dB(a)
Fio2: 21%~100%
Customization:
Diamond Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
YSAV-5B-M2
CPAP Pressure
0.3~1.0kpa(3~10CMH2o)
Gas-Source Require
Oxygen 0.3MPa~0.4MPa
Battery
Built-in Backup Battery
Transport Package
Wooden Case
Specification
CE certificate
Trademark
YSENMED
Origin
China
Production Capacity
5, 000 Sets/Year

Product Description

YSAV-5B-M2 CPAP Infant Respirator Mobile Infant Bubble CPAP System with Air Compressor
Ysav-5b-M2 CPAP Infant Respirator Mobile Infant Bubble CPAP System with Air Compressor


Introduction
Bubble CPAP is a special medical equipment for supporting of babies' breath which devised and manufactured based on the wide application of closed continuous NCPAP in department of pediatrics. It uses on the course of ventilation treatment of Nasal-CPAP for premature, neonate, infant to children below 14 year old. The mode of CPAP can reduce babies' work of breathing effectively, while keeping the autonomous respiration.

Features
1. Assemble the main machine, humidifier and the optional compressor together, to save space.
2. Inside the Air-oxygen Blender, and the FIO2 is continuous and controllable.
3. Adjusting the oxygen concentration and the flow respectively.
4. It is easy to monitor the FIO2, to ensure the safety of oxygen.
5. High accuracy of CPAP regulating, combine the system pressure monitor with safety valve to ensure the safety of patient.
6. The main machine does not need electric power, and match with support arm.
7. The optional compressor adopts imported pump, with little water and low noise.
8. Match with humidifier that controlled by electric or automatically, to ensure the best situation of humidifier.
9. The light and diversified tubes and rhinobyons reduce the patient's WOB; the convenient fixed device reduces the compressor of patient's head and face, and the injure of nasal septum.
10. It is applied to PIIUC, NICU, PICU and first aid room widely.

Technical parameter
Ventilation mode: CPAP mode
FIO2: 21%~100%
Flow: 0~18LPM
CPAP adjustment: 0~1.0kPa(0~10cmH2O)

Monitor
Pressure monitor: 0~2.5kPa(0~25kPa)
FIO2: 21%~100%
Pressure safety valve: if the pressure in tubes over 1.5 times than adjusting parameter, the safety valve will open automatically.

Alarm
Differential alarm: differential pressure between 0.05MPa~0.12MPa, sound alarm.
Low battery alarm: when the voltage reduce to 6.8±V0.5V,LCD will alarm "LOW BATTERY".

Common parameter
Size: W*H*D 24.7cm*17.5cm*21cm
Weight: about 6KG
Gas-source: 0.3MPa~0.4MPa




We listed some hospital operation room items basic items for your reference as below:
operation room anesthesia machine
ventilator
operating lamp
operation table
Pendant
medical drill and saw
ECG
patient monitor
Defibrillator
infusion pump
Electrocoagulation
oxygen generator
electric suction device
autoclave sterilizer
 

Ysav-5b-M2 CPAP Infant Respirator Mobile Infant Bubble CPAP System with Air Compressor

Ysav-5b-M2 CPAP Infant Respirator Mobile Infant Bubble CPAP System with Air Compressor
Ysav-5b-M2 CPAP Infant Respirator Mobile Infant Bubble CPAP System with Air Compressor

Ysav-5b-M2 CPAP Infant Respirator Mobile Infant Bubble CPAP System with Air Compressor
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now