Customization: | Available |
---|---|
Power Supply: | 110/220V 60/50Hz |
Height Adjustable Range: | 0-20cm |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1. Three modes of control: manual, skin temperature and mattress temperature
2. Alloyed bracket, fastness
3. Microprocessor based servo controlled temperature system
4. Control panel displayed by VFD
5. Digital skin temperature sensor, the data is exact and stabilizability
6. High sensitivity and untouched detector to inspect mattress temperature
7. Alarm functions for safety include Power failure , temperature deviation ,Temperature probe failure, over temperature.
8. APGAR timer to record therapy time
9. Observe light angle can be adjusted + 90º, and the brightness adjusted
10. Heater head can be adjusted + 90º horizontally
11. Electric infant bed tilt angle is + 10º, transparent protector folded
12. Convenient X-ray cassette under infant bed
13. Electric height adjusted suit for operation
14. Adopts anti-explosion micro crystal quartz infrared radiation tube for its radiation source, the heating is quick
and life-span is long
15. Alarms are audible and visual
16. A second thermal cut-out function for more safety
17. Skin temperature sensor failure protect function avoid over temperature
Standard configuration
1. Main body (including the radiant source, control system, infant bed, electric lift stand), I.V.pole, skin sensor, mattress,
one drawer, transparent protector, castors
2. Optional parts: low pressure aspirator; oxygen supply system, LED phototherapy unit.
Technical data:
1. Power supply: 110/220V 60/50Hz
2. Power input: ≤1000VA
3. Operating condition
An ambient Temperature: 18°C-30°C
An ambient Relative Humidity: 30%--75%RH
Atmospheric Pressure: 700~1060 hPa
An ambient Air Velocity <0.3m/s
4.Range of Skin Temperature control: 32°C~38°C
5. Temperature control accuracy: ≤0.5°C
6. Alarms functions:
a. Over temperature :> 39°C
b. A second thermal cut- out: 40°C
c. Sensor alarm: skin temperature sensor failure
Mattress temperature sensor failure
Room temperature sensor failure
d. Power failure
7.Mattress temperature uniformity : <2°C
8. Skin temperature sensor accuracy: ≤0.3°C
9. Mattress temperature sensor accuracy: ≤0.4°C
10. Room temperature sensor accuracy: ≤0.3°C
11. Warm-up time: ≤30min
12. Height adjustable range: 0-20CM
13. Bed tilt angle: + 10°
14. APGAR timer range: ≤24h
15. Heater head horizontal: ±90°
16. Mattress size: 76CM X 65CM
17. Distance from heater to mattress: 90CM
18. Whole unit size: 70CMX 110CMX 180CM (180-200CM)
19. Castor load: 1pc≤200kg 4pcs≤800kg
Transport and storage
1. Environment Temperature:-40°C~ +55°C
2. Environment Relative Humidity: ≤95%
3. Atmospheric Pressure: 500~1060hPa
Package:
package | Each unit is packed one case |
Size | 114CMX 94CM X 104CM |
Gross weight | ≤190KG |
We listed some hospital basic items for your reference as below:
One-stop shopping Hospital medical equipment |
X ray room | X ray machine |
Processor | ||
X ray film | ||
Cassette | ||
Intensifying screen | ||
Lead clothings(lead glove, lead glasses, Lead cap, lead apron, lead collar) |
||
Ultrasound | B/w 2D ultrasound | |
2/3/4D color ultrasound | ||
Laboratory room | Chemistry analyzer | |
Hematology analyzer | ||
Microplate elisa reader | ||
Microplate washer | ||
Centrifuge | ||
Pipette | ||
Water bath | ||
Urine analyzer | ||
Operation room | Anesthesia machine | |
Ventilator | ||
Operating lamp | ||
Operation table | ||
Pendant | ||
Medical drill and saw | ||
ECG | ||
Patient monitor | ||
Defibrillator | ||
Infusion pump | ||
Electrocoagulation | ||
Oxygen generator | ||
Electric suction device | ||
Autoclave sterilizer |