Type: Electrosurgical Unit
Kind: Electrosurgical Unit
Certification: CE, ISO13485, Electrocoagulation
Group: All
LCD Display: With LCD Display
Bipolar Coagulation: 1W~70W( Load 200Ω)
Customization:
Diamond Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
YSESU-2000I5
Pure Cut
1W~300W( Load 800Ω)
Blend1
1W~200W(Load 800Ω)
Bipolar Cut
1W~120W( Load 200Ω)
Contact Coag: 1W~80W( Load 800Ω)
1W~80W( Load 800Ω)
Operating Frequency
416kHz
Power Rating
1100va±10%
Blend2
1W~250W(Load 800Ω)
Forced Coag
1W~120W( Load 800Ω)
Product Name
Electrocoagulation
Transport Package
Standard Export Wooden Case
Specification
ISO certificate
Trademark
ysenmed
Origin
China
Production Capacity
1, 000set/Month, Electrocoagulation

Product Description

Hopital Operation Room Electro Surgical Unit Electrocoagulation  
Model:YSESU-2000I5


Hopital Operation Room Electro Surgical Unit Electrocoagulation



Main Features

 
1.Max 300W Electrosurgical Generator, with mono-polar and bipolar function.
2.Five working modes: pure cut, blend, spray coag, forced coag, bipolar coag.
3.Wide clinical applications, such as the general surgery, thoracic surgery, orthopedic surgery, 
cardiology, gynecology, 

urology(under water TUR), oncology, neurosurgery, etc.
4.Microprocessor controlled, digital display. With audible and visual indicators and errors codes 
during the process of outputting.

5.Return Electrode Monitoring system and Power Peak System, minimizing the risk of tissue 
damage. 

6. Both hand and foot controlled.
7. Separate power display and outlet socket for mono-polar cut, mono-polar coag, bipolar cut and bipolar coag, each output can be individually configured.
8. Memory for at least 10 frequently used programs.
9. Remote control function. The surgeon can adjust the outputs by power control ESU pencil. 
10. The ESU unit can be connected with laparoscope and endoscope, etc.
11.Protection against over-voltage and over-current.
12. Defibrillation protected.
13.Mounted on a 4 wheels cart(optional).
14.Meets the requirements of international safety standards EN60601-1 and EN60601-2.



Technical Specifications:
Power 220V±22V, 50Hz±1Hz(110V±11V, 60Hz)
Operating frequency 512KHz
Power rating 1100VA±10%
 
Five working modes:
Mono-polar Cut   Pure cut 1W~300W( Load 800Ω)
Blend 1W~200W(Load 800Ω)
Mono-polar Coag Spray Coag 1W~80W( Load 800Ω)
Forced Coag 1W~ 1W~120W( Load 800Ω)
Bipolar Bipolar Coagulation 1W~50W( Load 200Ω)
Power Consumption ≤1100VA
 
Configuration Sheet 
Electrosurgical Pencil 5pcs
Electrosurgical Pad 10pcs
Electrosurgical pad cable 1pcs
Footswitch 1set
Bipolar Forceps 1pcs
Bipolar forceps cable 1pcs
      
 


 model:YSESU-2000B



Hopital Operation Room Electro Surgical Unit Electrocoagulation





 

Main Features:

Deep hemostasis, foot control outputs, mild hemostasis.

According to the depth of hemostasis, the output mode stops automatically.

The output power will not reduce when operating in dry and bleeding spot.

Foot control mode: When the tissue reach the coagulation effects, the output power

declines slowly.

Auto mode: when the tissue or blood vessel was coagulated, output power drops off sharply,

to keep the forceps from sticking and over burnt for tissues.

Low voltage effectively reduces forming of the sparking of forceps, stimulating for the

neuromuscular, to increase the security.

Microcontroller system allows this unit can be used in many delicate surgery.

 Bipolar cut :macro bipolar.

 

Technical specifications:

Two working modes: bipolar coag,bipolar cut

Power: 220V±22V(110V±11V) 50Hz±1Hz

Working frequency:1024KHz

Output power:

1) bipolar coag:1-120W(load 200Ω)

 2) bipolar cut:1-120W(load 200Ω)

 

Configuration

Footswitch                                               1set

None sticky bipolar Forceps and cable        1set

Bipolar cut  pencil                                     1piece





 

Microprocessor controlled digital display high frequency electrotome

Model:YSESU-2000I



Hopital Operation Room Electro Surgical Unit Electrocoagulation


 

Main features:

1. Six working modes: pure cut, blend1, blend2, contact coag, forced coag, bipolar coag.
2.Max 300W Electrosurgical Generator, with mono-polar and bipolar function. 
3.Wide clinical applications, such as the general surgery, thoracic surgery, orthopedic surgery, 

cardiology, gynecology, urology(under water TUR), oncology, neurosurgery, etc.
4.Microprocessor controlled, digital display. With audible and visual indicators and errors codes 
during the process of outputting.

5. Return Electrode Monitoring system and Power Peak System, minimizing the risk of tissue 
damage. 

6.Both hand and foot controlled.
7.Separate power display and outlet socket for mono-polar cut, mono-polar coag, bipolar cut and bipolar coag, each output can be individually configured.
8. Remote control function. The surgeon can adjust the outputs by power control ESU pencil. 
9.The unit always remember the last setting when it turned off.
10.The ESU unit can be connected with laparoscope and endoscope, etc.
11. Protection against over-voltage and over-current.
12.Defibrillation protected.
13.Convection refrigeration without ventilator.
14. Mounted on a 4 wheels cart(optional).
15.Meets the requirements of international safety standards EN60601-1 and EN60601-2-2.

Technical Specifications
Power: 220V±22V, 50Hz±1Hz(110V±11V, 60Hz)
Operating frequency: 512KHz  
Power rating: 1100VA±10%

 

Six working modes:

 

1.Mono-polar Cut 
a) Pure cut:1W~300W( Load 800Ω)
b) Blend1:1W~200W(Load 800Ω)
c) Blend2:1W~250W(Load 800Ω)
2.Mono-polar Coag
d) Contact Coag:1W~80W( Load 800Ω)
e) Forced Coag:1W~120W( Load 800Ω)
3.Bipolar
f) Bipolar Coagulation: 1W~70W( Load 200Ω)
4.Power Consumption: ≤1100VA





Model: YSESU-2000A


Hopital Operation Room Electro Surgical Unit Electrocoagulation

 

Main Features

Max 300W Electrosurgical Generator, with mono-polar and bipolar function.

Seven working modes: pure cut, blend1, blend2, contact coag, forced coag, bipolar coag,
bipolar cut.

Wide clinical applications, such as the general surgery, thoracic surgery, orthopedic surgery, cardiology, gynecology, urology(under water TUR), oncology, neurosurgery, etc.

Microprocessor controlled, LCD touch screen display. With audible and visual indicators and errors codes during the process of outputting.

Return Electrode Monitoring system and Power Peak System, minimizing the risk of tissue damage.

Both hand and foot controlled.

Separate power display and outlet socket for mono-polar cut, mono-polar coag, bipolar cut and bipolar coag, each output can be individually configured.

The unit always remember the last setting when it turned off.

Remote control function. The surgeon can adjust the outputs by power control ESU pencil.

The ESU unit can be connected with laparoscope and endoscope, etc.

Protection against over-voltage and over-current.

Defibrillation protected.

Convection refrigeration without ventilator.

Mounted on a 4 wheels cart(optional).

Meets the requirements of international safety standards EN60601-1 and EN60601-2.

 

Technical Specifications

Power: 220V±22V, 50Hz±1Hz(110V±11V, 60Hz)

Operating frequency: 416KHz

Power rating: 1100VA±10%

Seven working modes:

Mono-polar Cut

a) Pure cut:1W~300W( Load 800Ω)

b) Blend1:1W~200W(Load 800Ω)

c) Blend2:1W~250W(Load 800Ω)

Mono-polar Coag

d) Contact Coag:1W~80W( Load 800Ω)

e) Forced Coag:1W~120W( Load 800Ω)

Bipolar

f) Bipolar Coagulation: 1W~70W( Load 200Ω)

g) Bipolar Cut: 1W~120W( Load 200Ω)

Power Consumption: ≤1100VA

 

Configuration Sheet

Electrosurgical Pencil      5pcs

Electrosurgical Pad        10pcs

Electrosurgical pad cable   1pcs

Double Footswitch         1set

Bipolar Forceps           1pcs

Bipolar forceps cable       1pcs

Manufacturer clinic medical lab equipment

Yuesenmed provides various equipment for medical lab. We guarantee high quality, reasonable prices and fast delivery. 

We are a company aiming to make one stop shopping for our customers. We equiped medical lab with many kind of items like chemistry analyzer, blood analyzer, centrifuge and so on.

We listed some medical lab basic items for your reference as below:

 

 

One-stop shopping for laboratory room chemistry analyzer (auto and semi auto models)
notebook computer for the 
automatic chemistry analyzer. 
water bath for Semi-auto chemistry analyzer.
hematology analyzer.
blood gas analyzer.
urine analyzer.
coagulation analyzer.
immunochramato reader. 
blood bank refrigerator.
pharmaceutical refrigerator.
microplate elisa reader.
microplate washer.
centrifuge.
pipette.
rotator.
autoclave sterilizer.


Please let us know your specific request. We would like to recommend you the most suitable
model based on your information.  

Model:YSESU-2000B
 

Main Features For Electrosurgical Unit
 
a)  Deep hemostasis, foot control outputs, mild hemostasis.
 
b) According to the depth of hemostasis, the output mode stops automatically. 
    The output power will not reduce when operating in dry and bleeding spot.
 
c) Foot control mode: When the tissue reach the coagulation effects, the output power 
   declines slowly.
 
d) Auto mode: when the tissue or blood vessel was coagulated, output power drops 
    off sharply, to keep the forceps from sticking and over burnt for tissues.
 
e) Low voltage effectively reduces forming of the sparking of forceps, stimulating for 
    the neuromuscular, to increase the security.
 
f)  Microcontroller system allows this unit can be used in many delicate surgery.
 
g)  Bipolar cut :macro bipolar.

 
Technical specifications For bipolar electrocoagulation machine :
 
1) Two working modes: bipolar coag,bipolar cut
 
2) Power: 220V±22V(110V±11V) 50Hz±1Hz
 
3) Working frequency:1024KHz
 
4)Output power:
 
  a) bipolar coag:1-120W(load 200Ω)
 
  b) bipolar cut:1-120W(load 200Ω)

 
Configuration 

 
Footswitch   1set
None sticky bipolar Forceps and cable   1set
Bipolar cut  pencil   1piece

Please let us know your specific request. We would like to recommend you the most suitable
model based on your information.

Hopital Operation Room Electro Surgical Unit Electrocoagulation
Hopital Operation Room Electro Surgical Unit Electrocoagulation
Hopital Operation Room Electro Surgical Unit Electrocoagulation
Hopital Operation Room Electro Surgical Unit Electrocoagulation
 
 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now