Ysecg8000s Hospital Medical ECG Stress Test System with Treadmill

Product Details
Customization: Available
Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: ECG
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Terms of Payment
LC, T/T, Western Union, Money Gram
OEM/ODM Availability
Yes
  • Ysecg8000s Hospital Medical ECG Stress Test System with Treadmill
  • Ysecg8000s Hospital Medical ECG Stress Test System with Treadmill
  • Ysecg8000s Hospital Medical ECG Stress Test System with Treadmill
  • Ysecg8000s Hospital Medical ECG Stress Test System with Treadmill
  • Ysecg8000s Hospital Medical ECG Stress Test System with Treadmill
  • Ysecg8000s Hospital Medical ECG Stress Test System with Treadmill
Find Similar Products

Basic Info.

Model NO.
YSECG8000S
Certification
CE, ISO13485
Group
All
Name
ECG Stress Test System
Application
Hospital Medical
Voltage
220V/50Hz
Lead
Standard 12-Lead
Time Constant
>=3.2s
Patient Lead Current
<10 Ua
Calibration Voltage
1mv
Input Loop Current
<=50na
Communicate Mode
WiFi
Transport Package
Wooden Case
Specification
225*96*66cm, 230KG
Trademark
YSENMED
Origin
China
HS Code
9022199090
Production Capacity
5, 000 Sets/Year

Product Description

YSECG8000S Hospital Medical ECG Stress Test System With Treadmill

 

Ysecg8000s Hospital Medical ECG Stress Test System with TreadmillYsecg8000s Hospital Medical ECG Stress Test System with TreadmillYsecg8000s Hospital Medical ECG Stress Test System with Treadmill

Introduction

 

The Stress ECG Analysis System is consist of sampling hardware device, special software system and exercise equipment. Its functions include 12 leads ECG synchronously sampling, and data storage, ST segment analysis, ECG review in dynamic/static/superimposed during the whole exercise process, and trend chart analysis of multiple parameters, multiple printable report, etc. The patient's exercise state can be recorded timely and accurately, which reflects patient's heart function, providing reliable data for doctors in diagnoses.


 

Features

 

1. Print ECG waveform in real-time during sampling process, record and save ECG data of whole process.
2. Observation of the changes of ST segment in real-time, enlargement display of user selected lead, automatic calculation of ST related data.
3. Adopt anti-interference technology to ensure the stabilization of baseline, reduce the effect on ECG waveform from EMG interference, baseline drift and AC interference.
4. Available for both standard and user-defined exercise scheme, automatic instantaneous notice of print and BP measure can be set according to exercise phrase.
5. Operator can mark events during exercise, the ECG waveform of marked event can be compared with current waveform. The event can be observed, edited and printed after excise.
6. Display and print of all kinds of trend chart. Mainly including: HR, BP, METS, HR*BP, exercise trend, ST segment level/influence/slope/3D/J level and ST/HR, etc.
7. Dynamic/static review function after exercise, representation of the whole exercise testing process. 
8. Case Import/Export function. Compress the case for storage, which takes up less disk space. The compressed case shall be associated with the file type in operation system. This will make the import operation much more simple and quick.
9. System setting function includes multiple setting items. For example, switching Chinese/English language, format and mode of displaying waveform (12 leads * 1column / 6leads * 1column / 6leads * 2columns / 3leads * 2columns / 3 leads * 1column, etc), color of background, print related setting, filter setting and displaying of optional parameters, etc.
10. Provide multiple functional tools, which are used for device management, cases statistics and other operations.
11. Wireless mode of ECG data sampling, improves the anti-interference capability.
12. Supportive for variety types of exercise equipment

 

 

Performance

 

Patient leak current: <10µA
Input impedance: ≥50MΩ
Frequency response: 0.05Hz~150Hz (-3dB~+0.4dB)
Time constant: ≥3.2s
Common mode rejection ratio (CMRR):>60dB, >100dB (filter on)
Calibration voltage: 1mV
Sampling frequency: max. 1000 Hz
Sampling accuracy: max. 24bits
Input loop current: ≤50nA
Polarization resistance voltage: ±500mV
Noise level: ≤15µVp-p
Safety type: internally powered equipment, type BF

 

 

Accessories

 

Wireless network card 1pc
Lead cables 1pc
Electrodes 1pc
Grounding wire 1pc
Velcro 2pcs
Serial-port cable 1pc
CD 1pc
Software dog 1pc
Serial-port card 1pc

Physical Characteristic

Dimension: 94mm(L) *66mm(W)*31mm(H)
Weight: about 94.6g (without battery)

Optional configuration

See the BOM for details. 


Ysecg8000s Hospital Medical ECG Stress Test System with Treadmill
Ysecg8000s Hospital Medical ECG Stress Test System with Treadmill
Ysecg8000s Hospital Medical ECG Stress Test System with Treadmill
Ysecg8000s Hospital Medical ECG Stress Test System with Treadmill

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More