Medical Hospital Infant Newborn Baby Neonatal Radiant Warmer YSBN-100S
Brief introduction:
1. Microprocessor based servo controlled temperature system.
2. The microprocessor-controlled unit allows for three settings: Pre-warm, manual or automatic.
3. Alarm functions for safety includes:
Power failure, temperature deviation,
Temperature sensor failure, over temperature.
4. APGAR timer to record therapy time
5. Convenient X-ray cassette under infant bed
6. Heater head can be adjusted + 90º Horizontally
7. Tilt angle of infant bed is adjustable
8. Halogen Observe light angle is adjustable
9. Transparent protector folded
10. Adopts anti-explosion micro crystal quartz infrared radiation tube for its radiation source, the heating is quick and life-span
Is long
11. Alarms are audible and visual
12. A second thermal cut-out function for more safety
13. Skin temperature sensor failure protect function avoid over temperature
14. Temperature deviation can be amended in front panel directly
Standard configuration
Main body (including the radiant source, control system, infant bed, bracket), X-ray cassette, Observe light, I. V. Pole, skin
Temperature sensor, tray, mattress, transparent protector, castors.
Optional parts: Drawer, RS-232(485) connector
Technical data:
1. Power supply: 110/220V 60/50Hz
2. Power input: ≤ 1200VA
3. Operating condition
An ambient Temperature: 18° C-30° C
An ambient Relative Humidity: 30%--75%RH
Atmospheric Pressure: 700~1060 hPa
An ambient Air Velocity <0.3m/s
4. Temperature control: 32° C~38° C
5. Temperature control accuracy: ≤ 0.5° C
6. Mattress temperature uniformity: <2° C
7. Skin temperature sensor accuracy: + 0.3° C
8. Warm-up time: ≤ 30min
9. Infant bed tilt angle: + 10°
10. APGAR timer range: ≤ 24h
11. Heater head horizontal: ± 90°
12. Mattress size: 67CM X 54CM
13. Distance from heater to mattress: 90CM
Transport and storage
Environment Temperature: -40° C~ +55° C
Environment Relative Humidity: ≤ 95%
Atmospheric Pressure: 500~1060hPa
Package:
PackageEach unit is packed one case
Size120CMX 70CM X 96CM
Gross weight≤ 90KG
Related product:
YSBN-200 medical infant radiant warmer
Brief introduction:
1. Three modes of control: Manual, skin temperature and mattress temperature
2. Alloyed bracket, fastness
3. Microprocessor based servo controlled temperature system
4. Control panel displayed by VFD
5. Digital skin temperature sensor, the data is exact and stabilizability
6. High sensitivity and untouched detector to inspect mattress temperature
7. Alarm functions for safety include
Power failure, temperature deviation
Temperature probe failure, over temperature
8. APGAR timer to record therapy time
9. Observe light angle can be adjusted + 90º , and the brightness adjusted
10. Heater head can be adjusted + 90º Horizontally
11. Electric infant bed tilt angle is + 10º , transparent protector folded
12. Convenient X-ray cassette under infant bed
13. Electric height adjusted suit for operation
14. Adopts anti-explosion micro crystal quartz infrared radiation tube for its radiation source, the heating is quick and life-span is long
15. Alarms are audible and visual
16. A second thermal cut-out function for more safety
17. Skin temperature sensor failure protect function avoid over temperature
Standard configuration
1. Main body (including the radiant source, control system, infant bed, electric lift stand), I. V. Pole, skin sensor, mattress, one drawer, transparent protector, castors
2. Optional parts: Low pressure aspirator; Oxygen supply system, LED phototherapy unit.
Technical data:
1. Power supply: 110/220V 60/50Hz
2. Power input: ≤ 1000VA
3. Operating condition
An ambient Temperature: 18° C-30° C
An ambient Relative Humidity: 30%--75%RH
Atmospheric Pressure: 700~1060 hPa
An ambient Air Velocity <0.3m/s
4. Range of Skin Temperature control: 32° C~38° C
5. Temperature control accuracy: ≤ 0.5° C
6. Alarms functions:
A. Over temperature: > 39° C
B. A second thermal cut- out: 40° C
C. Sensor alarm: Skin temperature sensor failure
Mattress temperature sensor failure
Room temperature sensor failure
D. Power failure
7. Mattress temperature uniformity: <2° C
8. Skin temperature sensor accuracy: ≤ 0.3° C
9. Mattress temperature sensor accuracy: ≤ 0.4° C
10. Room temperature sensor accuracy: ≤ 0.3° C
11. Warm-up time: ≤ 30min
12. Height adjustable range: 0-20CM
13. Bed tilt angle: + 10°
14. APGAR timer range: ≤ 24h
15. Heater head horizontal: ± 90°
16. Mattress size: 76CM X 65CM
17. Distance from heater to mattress: 90CM
18. Whole unit size: 70CMX 110CMX 180CM (180-200CM)
19. Castor load: 1pc≤ 200kg 4pcs≤ 800kg
Transport and storage
1. Environment Temperature: -40° C~ +55° C
2. Environment Relative Humidity: ≤ 95%
3. Atmospheric Pressure: 500~1060hPa
Package:
Each unit is packed one case
Size: 114CMX 94CM X 104CM
Gross weight: ≤ 190KG