Medical Equipment Hospital Product Dialyzer Reprocessing Machine Hemodialysis Reprocessor
Contact Supplier
Product Highlights
- World's First Automatic Reprocessing: YSDRM168A/B are the first automatic dialyzer reprocessing machines globally.
- Dual Workstation Option: YSDRM168B features a double workstation for enhanced efficiency.
- Comprehensive Safety Testing: Automatically tests blood chamber capacity and membrane integrity.
- Patented Pulsating Current Technology: Uses positive/reverse rinse and UF to extend dialyzer lifespan.
- Water Saving Design: Consumes less than 8L of water per dialyzer cycle.
- PC Database Management: Create, save, and search patient databases with barcode scanning.
- Anti-Cross Infection Control: Extra blood port header prevents infection among patients.
- CE and ISO13485 Certified: Meets international safety and quality standards for medical devices.
Product Attributes
- Customization
- Available
- Certification
- CE, ISO13485
- Type of Body Fluid-Processing Device
- Blood Component Separator
- Model NO.
- YSDRM168A
- MOQ
- 1 PCS
- Power Supply
- AC 220V±10%, 50Hz-60Hz, 2A
- Input Power
- 150W
- Water Input Temperature
- 10℃-40℃
- Trademark
- Ysenmed
- Origin
- China
- Production Capacity
- 300PCS/Month
Product Images of Medical Equipment Hospital Product Dialyzer Reprocessing Machine Hemodialysis Reprocessor
Find Similar Products
Product Description
Model : YSDRM168A
Function1. YSDRM168A /YSDRM168B dialyzer reprocessing machine are the first automatic dialyzer reprocessing machine in the world, and YSDRM168B with double workstation. Our perfectness comes from professional and advanced technology, that makes our products legal, safe, and stable.
2. YSDRM168A / YSDRM168B Dialyzer Reprocessing Machine are the main device for hospital to sterilize, clean, test and affuse reusable dialyzer used in hemodialysis treatment.
3. Procedure of Reusing Processing:
[Rinse]----Using RO water to rinse dialyzer.
[Clean]----Using disinfectant to clean dialyzer.
[Test] -----Testing blood chamber capacity of dialyzer and whether the membrane is broken or not.
[Disinfect] ---Using disinfectant to affuse dialyzer.
4. Be used in hospital only.
Technical Parameter
Size & Weight Size: YSDRM168A 470mm×380mm×480mm (L*W*H)
YSDRM168B 480mm×380mm×580mm (L*W*H)
Weight: YSDRM168A 30KG
YSDRM168B 35KG
Power Supply:AC 220V±10%, 50Hz-60Hz, 2A
Input power: 150W
Water input pressure: 0.15~0.35 MPa (21.75 P.S.I.~50.75 P.S.I.)
Water input temperature: 10ºC~40ºC
Minimum water Inlet flow : 1.5L/min
Reprocessing time: about 12 minutes per cycle
Work environment: temperature 5ºC~40ºC at relative humidity of no more than 80%.
Storage temperature should be between 5ºC~40ºC at relative humidity of no more than 80%.
Features
PC work station:can create,save, search the patients database; operation standard of nurse; easily scan the code to send the signal for reprocessor running automatically;
Effective when reprocessing single or double dialysers at one time. Model - W-F-168-B
Cost-effective: compatible with many brands of disinfectant.
Accuracy & safety: automatic disinfectant dilution
Anti-cross infection control: extra blood port header to prevent infection among patients.
Record function: print reprocessing data, such as name, sex, number of case, date, time, etc.
Double printing: built-in printer or optional external printer(adhesive sticker)
Why to choose YSDRM168B Dialyzer Reprocessing:
1. Adopting pulsating current oscillation technique, in the form of positive and reverse rinse as well as positive and reverse UF to eliminate the leftover in dialyzer in a short time to resume cell volume, so as to prolong the life span of dialyzers.
2. The accurate and efficient test of TCV and blood leak, reflect directly the situation of reprocessing, thus assured the safety of the whole course.
3. Rinse, cleaning, testing and disinfectant affusion could be done either respectively or together, suiting different requirements.
4. Functions like reprocessing system setting, disinfection of machine and debugging are introduced under the main menu.
5. The auto setting of reprocessing run the evacuation before affusion, in order to prevent the redilution of disinfectant.
6. The special design of concentration detection ensures the accuracy of disinfectant and safety of disinfection.
7. Human-oriented design of touch control LCD makes the operation easy.
8. Only a tap and the whole reprocessing would run automatically.
9. The stored information of model capacity ultra filtration coefficient etc makes operation easy and accurate.
10.Functions of troubleshooting tips and shooting alarming reflect the situation timely to the operator.
11.The adoption of 41 patents improved the quality while decreased water use (less than 8L once for per dialyzer)
Contraindication
This machine is designed, made and sold for reusable dialyzer only.
The following five kinds of dialyzers can not be reused in this machine
(1) the dialyzer which has been used by the positive hepatitis B virus patient
(2) the dialyzer which has been used by the positive hepatitis C virus patient
(3) the dialyzer which has been used by the HIV carriers or HIV AIDS patient
(4) the dialyzer which has been used by other patient with blood-infectious disease
(5) the dialyzer which has been used by the patient who has an allergy to disinfectant used in reprocessing.




About the Supplier
This supplier has been audited by BV. Verify the report on the official BV website with ID "MIC-ASR231016". Items marked "" are certified.
Company Profile
Guangzhou Yueshen Medical Equipment Co., Ltd. (hereinafter Referred To As Yuesen Med), Compounded With The R&D And Sale Of Medical Device, Is A Leading Supplier Of Medical Equipment, Especially In The Field Of Medical X-ray Machine.
Headquartered In Guangzhou, "Yuesen Med" Covers The Business Of Medical X-ray Machines, X-ray Accessories, Ultrasound Scanners, Hospital Sterilizers, Anesthesia Machines, Ventilators, Clinical Lab Equipment, Operation Room Equipment, Hospital Furniture, And Other Medical Equipment. Based On Mutual Trust & Good Service, Our Mission Is To Provide The Most Cost-effective Medical Equipment For Hospital Around The World.
In 2006, We Exported 125 Sets Of Medical X-ray Machine To Congo At One Time, Setting A Record Of Exporting Medical X-ray Machine To Foreign Countries. In 2008, The Same Customer Ordered Another 150 X-ray Units And 800 Sets Of Surgical Instruments. So Far, We Have Established Good Cooperation With Customers From 88 Countries Globally.
"Yuesen Med" Insists On The Idea Of "Reputation First, Customers Foremost", Which Is The Aim Of Our After-sale Service. We Have Established A Good After-sale Service Team, Providing Powerful Backup Force To Our Customers. In Recent Years, We Have Been Granted The "Nationwide Medical Device After-sale Service Advanced Unit".
Guangzhou Yueshen Medical Equipment Co., Ltd. is Committed To Be The Your Trustworthy Supplier And Exporter In The Field Of Medical Equipment.
Buy Medical Equipment, Please Choose Yuesen Med!
About Our Factory & Business Background
-
Business Type
- Trading Company
- Address
- 2nd Floor, Building C, Wanlima Industrial Park, No. 188, Xinye Road, Haizhu District, 510000, Prc, Guangzhou, Guangdong, China
-
Plant Area
- 2000 square meters
-
Number of Employees
- 32
-
Registered Capital
- 2,000,000 RMB
-
Terms of Payment
- LC, T/T, D/P, PayPal, Western Union, Small-amount payment
- International Commercial Terms(Incoterms)
- FOB, EXW, CFR, CIF, CIP, CPT, FCA
-
Average Lead Time
-
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays -
Nearest Port
- Guangzhou Port
Our Production Capability & Technical Expertise
-
Main Products
- Medical X-ray Machine, Ultrasound Scanner, Veterinary Equipment, Laboratory Equipment, Operation-room Equipment, Dental Equipment, Morgue Equipment, Endoscopes System, ENT Equipment, Maternal&infant Care, Medical waste Incinerator, Sterilization Equipment
-
R&D Engineers
- 6 people
Our Industry Experience & Global Business Record
-
Year of Establishment
- 2003-07-28
- Export Year
- 2003-01-01
- Main Markets
- North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe
FAQ
- What is the reprocessing time per cycle?
- The reprocessing time is approximately 12 minutes per cycle.
- Which dialyzers cannot be reused in this machine?
- Dialyzers used by patients with Hepatitis B, Hepatitis C, HIV/AIDS, other blood-infectious diseases, or allergies to the disinfectant cannot be reused.
- What is the minimum water inlet flow required?
- The minimum water inlet flow is 1.5L/min.
- Can the machine operate with different brands of disinfectant?
- Yes, the machine is cost-effective and compatible with many brands of disinfectant.
- Does the machine have a built-in printer?
- Yes, it has a built-in printer, and an optional external printer is also available.
- What is the lead time for production?
- The lead time is within 15 workdays for both peak and off-peak seasons.
- Is the machine suitable for home use?
- No, the machine is designed and intended for use in hospitals only.
Send your message to this supplier
Find Similar Products By Category
- Supplier Homepage
- Products
- Hemodialysis
- Dialyzer Reprocessing Machine
- Medical Equipment Hospital Product Dialyzer Reprocessing Machine Hemodialysis Reprocessor
Related Categories
Hot Searches
- China Medical Factories
- Medical Products Factories
- Medical Supply Factories
- Medical Device Factories
- Medical Product Machine
- Hospital Medical
- Medical Hospital Equipment
- Medical Equipment For Hospital
- Hospital Medical Device
- Dialyzer Reprocessing Machine Bulkbuy