YSTE0180C Automatic Chemistry Analyzer |
Specifications |
||||||||
Analyze System |
|||||||||
Throughput |
Maximun 300T/h,Constant 180T/h(non-ISE) |
||||||||
Theory |
Absorption spectronmetry,Transmission turbidimetry |
||||||||
Methodology |
End-point,Fixed-time,Kinetic,Monochromatic/bichromatic |
||||||||
Test according set up,random access |
|||||||||
Reaction plate |
Contain 81 reaction cuvettes |
||||||||
Miximun reaction time: 15 minutes |
Minimum reaction volume: 150 ul |
||||||||
Material of cuvettes |
Special UV-transparent optical glass |
||||||||
Can to be chose one-off cuvettes or automatically cuvettes washing |
|||||||||
Optical System |
|||||||||
Light Source |
Halogen-tungsten lamp |
||||||||
Photometer |
Reversed optics |
||||||||
Wavelength |
340nm-900nm wavelength option |
||||||||
Absorption |
0-4 Abs |
||||||||
Reagent/Sample Handling |
|||||||||
Sample volume |
2-100 ul,step by 0.1 ul |
||||||||
Sample plate |
Contain 60 sample positions |
||||||||
Reagent/Sample Probe |
Automatically checked,patent technology liquid level detection,collision protection probe cleaning:Automatic washing for both inside and outside |
||||||||
Samples cup |
Support one-off blood cuvettes,micro cups,plastic cuvettes |
||||||||
Reagent volume |
20-500 ul,step by 0.1 ul |
||||||||
Reagent plate |
Contain 60 reagent positions |
||||||||
Sample/reagent probe |
Collision protection liquid level detection;Internal and external probe washing;Probe depth adjustment automatically |
||||||||
Reagent bottle |
15ml & 30ml; Dead volume less than 0.5 ml |
||||||||
Temperature Control |
|||||||||
Maintenace free heater elements |
Temperature maintainance within 3 minutes |
Temperature fluctuation: ±0.1°C |
|||||||
Reaction temperature: 37±0.1°C |
Temperature of reagent compartment : 2-10°C |
||||||||
Operation system |
|||||||||
Software :WindowsXP,2000 |
Database: SQL Server |
||||||||
Data Storage |
Automatic store & copy;No time and volumn limit;Lifetime preservation |
||||||||
Print format |
Can be set up,offer several standard format |
||||||||
Calibration mode |
Linear curce type:Single-point linear,two-point linear and multi-point linear none linear;Curve type:Logistic-Log 4P,Logistic-Log5p,Spline,index automatically use best calibration curve and standard |
||||||||
QC Methods:Real time,within day & between day |
Quality Control Diagram: L-J,cumulative,twin plot |
||||||||
Control software |
Random set up,default westgard multi-rule |
||||||||
Status display |
Real time monitoring of reagent residual volume. Running status of reagent tray,samples tray |
||||||||
Adjustment |
Dynamic and real time display of running status;Intelligent carry over settings to adjust test sequence;Original reaction data record;Detail profile of alert messages |
||||||||
Setting |
Operation permission setting,Item setting,cross polution setting,cuvette blank setting |
||||||||
Others |
|||||||||
Water consumption:Less than 2 L per hour |
Power Supply: AC 220V±22V 50Hz±1Hz |
||||||||
Frequency:Maximun 600VA |
Dimension:782mm×581mm×545mm |
||||||||
Weight:60kg |
Accessory: Software |
medical hospital laboratory equipment | hematology analyzer | |
chemistry analyzer | semi-auto chemistry analyzer | |
automated chemistry analyzer | ||
centrifuge | high-speed centrifuge | |
low-speed centrifuge | ||
microplate reader | ||
microplate washer | ||
coagulation | ||
urine analyzer | ||
blood gas | ||
electrolyte analyzer | ||
specific protein | ||
immunoassay analyzer | ||
microscope | monocular microscope | |
binocular microscope |