Customization: | Available |
---|---|
Certification: | CE, ISO13485 |
Generator Maximum Power: | 40kw |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Specification and Features |
||
Generator | Norminal power | 32kW |
Maximum power | 40kW | |
Kvp range | 40-150kV | |
Current range | 10-400mA | |
Current time | 0.1-500mAs | |
Inverter frequency | 40kHz | |
|
||
X-ray Tube Toshiba E7843X |
Focal spot | 0.6mm/1.2mm |
Maximum input power | 20kW/46kW | |
Maximum input current | 370mA/760mA | |
Anode type | Rotating anode | |
Anode thermal capacity | 150kHU | |
Anode rotational speed | 3200r/min | |
Target angle | 12° | |
|
||
Collimator | Inherent filtration | 1.2 mm Al /70kV |
Rotation degree | ±90° |
Detector I Varian 4336R (wired) |
X-ray sensitive area | 42.4cm×35.3cm | |
Pixel size | 139μm | ||
DQE | 70%±5%(0 lp/mm, RQA5) | ||
Pixel matrix | 3072×2476 | ||
Limiting resolution | 3.6 lp/mm | ||
Cycle time | 10s | ||
A/D conversion | 14bit | ||
Image preview | ≤6s | ||
Detector Thales 3543EZ (wireless) |
X-ray sensitive area | 43cm×35cm | |
Pixel size | 148μm | ||
DQE | 66%(0 lp/mm, RQA5) | ||
Pixel matrix | 2880×2400 | ||
Limiting resolution | 3.4 lp/mm | ||
Cycle time | 10s | ||
A/D conversion | 16bit | ||
Image preview | ≤3s | ||
Detector Thales 2430EZ (Mini panel, wireless) |
X-ray sensitive area | 30cm×24cm | |
Pixel size | 148μm | ||
DQE | 70%±5%(0 lp/mm, RQA5) | ||
Pixel matrix | 2000×1600 | ||
Limiting resolution | 3.4 lp/mm | ||
Cycle time | 10s | ||
A/D conversion | 16bit | ||
Image preview | ≤1s | ||
Detector Iray 1417P(wired) |
X-ray sensitive area | 42cm×35cm | |
Pixel size | 150μm | ||
DQE | |||
Pixel matrix | 2800×2300 | ||
Limiting resolution | 3.3 lp/mm | ||
Cycle time | 9s | ||
A/D conversion | 14bit | ||
Image preview | ≤7s | ||
Detector Iray 1417V(wireless) |
X-ray sensitive area | 42cm×35cm | |
Pixel size | 150μm | ||
DQE | |||
Pixel matrix | 2880×2400 | ||
Limiting resolution | 3.4 lp/mm | ||
Cycle time | 9s | ||
A/D conversion | 14bit | ||
Image preview | ≤7s | ||
Detector PerkinElmer Xrpad 4336MED(wireless) |
X-ray sensitive area | 43.0cm×35.5cm | |
Pixel size | 100μm | ||
DQE | 75%(0 lp/mm, RQA5) | ||
Pixel matrix | 4320×3556 | ||
Limiting resolution | 5.0 lp/mm | ||
Cycle time | 9s | ||
A/D conversion | 16bit | ||
Image preview | ≤6s | ||
Position and physical specification | Tube vertical rotation angle | ±180° | |
Tube tilting angle | -30°~90° | ||
SID | 60-180cm | ||
Tube transverse motion | 72-124cm | ||
Cantilever type | cross telescopic arm | ||
Column rotation angle | ±270° | ||
Climbing capacity | 7°(Automatic) | ||
Dimension | 127cm×67cm×184cm | ||
Weight | 530kg | ||
Features | Motor driven | Yes | |
Exposure by battery power supply | Yes | ||
Remote control exposure | Yes | ||
Anti-collision braking | Yes | ||
Image workstation | Monitor | 19 inch touch screen, 1280×1024 | |
Processer | Core I3 dual core processer | ||
RAM | ≥4GB | ||
SATA | ≥500GB | ||
Operating System | windows 7 | ||
Operating software | DROC | ||
Software function | Patient registration and data edit | Yes | |
Expose parameter adjustion | Yes | ||
image view | Yes | ||
image process and output | Yes | ||
Data mannagement | Yes | ||
DICOM 3.0 | Yes |