Guangdong, China
Business Type:
Manufacturer/Factory, Trading Company
Terms of Payment:
LC, T/T, Western Union, Money Gram
OEM/ODM Availability:
Yes
OEM/ODM Service
Sample Available

ICU Syringe Pump, Syringe Pump, Syringe Infusion Pump manufacturer / supplier in China, offering Yszs-1800y Medical Portable ICU Drug Library Electric Double Syringe Infusion Pump, Yssy-820 Hospital Advanced Ce Approved Medical Infusion Pump Price, Yssy-820d Cheap Medical Drug Storage Hospital Infusion Pump and so on.

Diamond Member Since 2010
Audited Supplier
Supplier Homepage Products Operation Room Equipment Syringe & Infusion Pump Yszs-1800y Medical Portable ICU Drug Library Electric Double Syringe Infusion Pump

Yszs-1800y Medical Portable ICU Drug Library Electric Double Syringe Infusion Pump

Min. Order: 1 Piece
Port: Guangzhou, China
Production Capacity: 5, 000 Sets/Year
Payment Terms: L/C, T/T, Western Union, Money Gram
Type: Syringe Pump
Kind: Syringe Pump
Certification: ISO13485
Group: All
LCD Display: With LCD Display
Source: No

You Might Also Like

Loading...

Basic Info

Model NO.
YSZS-1800Y
Name
Syringe Pump
Trademark
YUESHEN
Transport Package
Carton
Specification
ISO certificate
Origin
Guangzhou
YSZS-810 Stackable (Single) syringe pump
 Yszs-1800y Medical Portable ICU Drug Library Electric Double Syringe Infusion Pump

Features & Functions:
1. Freely Stackable: Users can freely stack one syringe pump onto another to provide multiple Solutions, which have a wide range of clinical applications.
2. Stackable to be the maximum 8 channels.
3. Transfer the message between the Nurse-call System and the pumps.
4. Three working modes: rate mode, time-volume mode, dosage-weight mode.
5. Unique Voice Alarm system and accurate injection rate make the injection process safer and more reliable.
6. Have store many brands syringes,Automatically calibration and compatible with any brand syringes.
7. Large LCD screen displays working status.
8. KVO and Bolus functions.

 
Technical parameters:
Product nameStackable syringe pump YSZS-810
Unique Voice Alarm systemThe device triggered the voice prompt and stop injection automatically when there is any malfunction, making the infusion process safer and more reliable.
Flow rate50ml syringe:0.1~1500ml/h;
30ml syringe:0.1~900.0ml/h;
20ml syringe:0.1~600.0ml/h;
10ml syringe:0.1~300.0ml/h
The range of limiting volume0~999.9ml
The range of injected volume0~9999.9ml
Accuracy of flow rateWithin ±3%(Choose the syringe of specified manufacturer correctly. This accuracy of flow rate is not including the errors of syringe itself.)
Purge ratePurge rate of 50ml syringe:1500ml/h;
Purge rate of 30ml syringe:900.0ml/h;
Purge rate of 20ml syringe:600.0ml/h;
Purge rate of 10ml syringe:300.0ml/h
Alarm and warmsThe pump can give out alarming when injection soon finish, injection finishing, injection of limited amount finished, injection is blocked, syringe falls off, syringe is improperly installed, setting error, AC power has been pulled out, low battery and so on.  
Injection blockedChoose in the three kinds of occlusion alarm pressure according to the clinical requirements(High,Medium,Low)
KVO rate1ml/h
Fuse specificationF1AL/250V ,two fuses(installed inside pump)
Operating powerAC100~240.0V, 50/60Hz,  Power:≤30VA
Internal rechargeable battery: DC 11.1V,capacity≥1600mAh. The device could work constantly more than 4 hour at medium speed running mode, after the battery charged for 10 hours.
Operating environmenttemperature:+5~+40°C,  relative humidity:20~90%
Storing environmenttemperature:-30°C~+55, relative humidity:≤95%, ( No condensation state )
Atmospheric pressure860hPa~1060hPa
Safety levelClass II with insulated enclosure, internal power supply, BF-type continuous normal running equipment.
IP gradeIPX1
Dimensions280(L)×210(W)×130(H)(mm)
Weight2.2kg
AccessoriesPower line,operating manual,warranty card,product certification.
 

 
YSZS-810D Stackable (Single) syringe pump with drug library
 Yszs-1800y Medical Portable ICU Drug Library Electric Double Syringe Infusion Pump


Features & Functions:
1. Freely Stackable: Users can freely stack one syringe pump onto another to provide multiple Solutions, which have a wide range of clinical applications.
2. Stackable to be the maximum 8 channels.
3. Transfer the message between the Nurse-call System and the pumps.
4. Three working modes: rate mode, time-volume mode, dosage-weight mode.
5. Unique Voice Alarm system and accurate injection rate make the injection process safer and more reliable.
6. Have store many brands syringes,Automatically calibration and compatible with any brand syringes.
7. Large LCD screen displays working status.
8. KVO and Bolus functions.
9.Has drug library with more than 500 drugs.
10.Has 2000 records.
 
 
Technical parameters:
Product nameStackable syringe pump with drug library YSZS-810D
Unique Voice Alarm systemThe device triggered the voice prompt and stop injection automatically when there is any malfunction, making the infusion process safer and more reliable.
Flow rate50ml syringe:0.1~1500ml/h;
30ml syringe:0.1~900.0ml/h;
20ml syringe:0.1~600.0ml/h;
10ml syringe:0.1~300.0ml/h
The range of limiting volume0~999.9ml
The range of injected volume0~9999.9ml
Accuracy of flow rateWithin ±3%(Choose the syringe of specified manufacturer correctly. This accuracy of flow rate is not including the errors of syringe itself.)
Purge ratePurge rate of 50ml syringe:1500ml/h;
Purge rate of 30ml syringe:900.0ml/h;
Purge rate of 20ml syringe:600.0ml/h;
Purge rate of 10ml syringe:300.0ml/h
Alarm and warmsThe pump can give out alarming when injection soon finish, injection finishing, injection of limited amount finished, injection is blocked, syringe falls off, syringe is improperly installed, setting error, AC power has been pulled out, low battery and so on.  
Injection blockedChoose in the three kinds of occlusion alarm pressure according to the clinical requirements(High,Medium,Low)
KVO rate1ml/h
Fuse specificationF1AL/250V ,two fuses(installed inside pump)
Operating powerAC100~240.0V, 50/60Hz,  Power:≤30VA
Internal rechargeable battery: DC 11.1V,capacity≥1600mAh. The device could work constantly more than 4 hour at medium speed running mode, after the battery charged for 10 hours.
Operating environmenttemperature:+5~+40°C,  relative humidity:20~90%
Storing environmenttemperature:-30°C~+55, relative humidity:≤95%, ( No condensation state )
Atmospheric pressure860hPa~1060hPa
Safety levelClass II with insulated enclosure, internal power supply, BF-type continuous normal running equipment.
IP gradeIPX1
Dimensions280(L)×210(W)×130(H)(mm)
Weight2.2kg
AccessoriesPower line,operating manual,warranty card,product certification.

 
 
YSZS-810T Double Channel Syringe pump
Yszs-1800y Medical Portable ICU Drug Library Electric Double Syringe Infusion Pump

Features & Functions:
1.Three working modes: rate mode, time-volume mode, dosage-weight mode.
2.Unique Human Voice Alarm system and accurate injection rate make the injection process safer and more reliable.
3.Have store many brands syringes,Automatically calibration and compatible with any brand syringes.
4.Large LCD screen displays working status.
5.KVO and Bolus functions.
6.Two channels can work independently or together.
 
 
 
Technical parameters:
Product nameBYZ-810T Double Channel syringe pump
Flow rate50ml syringe:0.1~1500ml/h;
30ml syringe:0.1~900.0ml/h;
20ml syringe:0.1~600.0ml/h;
10ml syringe:0.1~300.0ml/h
The range of limiting volume0~999.9ml
The range of injected volume0~9999.9ml
Accuracy of flow rateWithin ±3%(Choose the syringe of specified manufacturer correctly. This accuracy of flow rate is not including the errors of syringe itself.)
Purge ratePurge rate of 50ml syringe:1500ml/h;
Purge rate of 30ml syringe:900.0ml/h;
Purge rate of 20ml syringe:600.0ml/h;
Purge rate of 10ml syringe:300.0ml/h
Alarm and warmsThe pump can give out alarming when injection soon finish, injection finishing, injection of limited amount finished, injection is blocked, syringe falls off, syringe is improperly installed, setting error, AC power has been pulled out, low battery and so on.  
Injection blockedChoose in the three kinds of occlusion alarm pressure according to the clinical requirements(High,Medium,Low)
KVO rate1ml/h
Fuse specificationF1AL/250V ,two fuses(installed inside pump)
Operating powerAC100~240.0V, 50/60Hz,  Power:≤30VA
Internal rechargeable battery: DC 11.1V,capacity≥1600mAh. The device could work constantly more than 4 hour at medium speed running mode, after the battery charged for 10 hours.
Operating environmenttemperature:+5~+40°C,  relative humidity:20~90%
Storing environmenttemperature:-30°C~+55, relative humidity:≤95%, ( No condensation state )
Atmospheric pressure860hPa~1060hPa
Safety levelClass II with insulated enclosure, internal power supply, BF-type continuous normal running equipment.
IP gradeIPX1
Dimensions280(L)×210(W)×255(H)(mm)
Weight3.6kg
AccessoriesPower line, operating manual, warranty card, product certification.

 
 
YSZS-810TU Double Channel Syringe pump with drug library
Yszs-1800y Medical Portable ICU Drug Library Electric Double Syringe Infusion Pump

Features & Functions:
 1.Three working modes: rate mode, time-volume mode, dosage-weight mode.
2.Unique Human Voice Alarm system and accurate injection rate make the injection process safer and more reliable.
3.Have store many brands syringes,Automatically calibration and compatible with any brand syringes.
4.Large LCD screen displays working status.
5.KVO and Bolus functions.
6.Two channels can work independently or together.
7.Has drug library with more than 500 drugs.
8.Has 2000 records.

 
Technical parameters:
Product nameYSZS-810TU Double Channel syringe pump
Flow rate50ml syringe:0.1~1500ml/h;
30ml syringe:0.1~900.0ml/h;
20ml syringe:0.1~600.0ml/h;
10ml syringe:0.1~300.0ml/h
The range of limiting volume0~999.9ml
The range of injected volume0~9999.9ml
Accuracy of flow rateWithin ±3%(Choose the syringe of specified manufacturer correctly. This accuracy of flow rate is not including the errors of syringe itself.)
Purge ratePurge rate of 50ml syringe:1500ml/h;
Purge rate of 30ml syringe:900.0ml/h;
Purge rate of 20ml syringe:600.0ml/h;
Purge rate of 10ml syringe:300.0ml/h
Alarm and warmsThe pump can give out alarming when injection soon finish, injection finishing, injection of limited amount finished, injection is blocked, syringe falls off, syringe is improperly installed, setting error, AC power has been pulled out, low battery and so on.  
Injection blockedChoose in the three kinds of occlusion alarm pressure according to the clinical requirements(High,Medium,Low)
KVO rate1ml/h
Fuse specificationF1AL/250V ,two fuses(installed inside pump)
Operating powerAC100~240.0V, 50/60Hz,  Power:≤30VA
Internal rechargeable battery: DC 11.1V,capacity≥1600mAh. The device could work constantly more than 4 hour at medium speed running mode, after the battery charged for 10 hours.
Operating environmenttemperature:+5~+40°C,  relative humidity:20~90%
Storing environmenttemperature:-30°C~+55, relative humidity:≤95%, ( No condensation state )
Atmospheric pressure860hPa~1060hPa
Safety levelClass II with insulated enclosure, internal power supply, BF-type continuous normal running equipment.
IP gradeIPX1
Dimensions280(L)×210(W)×255(H)(mm)
Weight3.6kg
AccessoriesPower line, operating manual, warranty card, product certification.
 
 

 
 Stackable Syringe Pump:  YSZS-1800C
 Yszs-1800y Medical Portable ICU Drug Library Electric Double Syringe Infusion Pump

Features:
  1. Stackable to be the maximum 8 channels.
  2. Compatible with disposable syringes
   from 5ml,10ml,20ml,30ml,50ml,60ml,universal type.
  1. High accuracy +/-2% after correct calibrated.
  2. Automatically detect the remained solution.
  3. Three work modes: Rate mode, Time mode and
Weight mode
  1. Unique LCD displayer.
  2. Bolus / Purge, KVO function.
8.  12 Hours continuous worked.
 
 
Technical Specifications
PARAMETERSPECIFICATION
Applicable syringes5ml,10ml,20ml,30ml,50ml,60ml of any standard
Accuracy+/- 2% with correct calibration
Rate mode50ml(60ml):0.1ml/h-1800.0ml/h (0.1ml/h step)
20ml(30ml):0.1ml/h-800.0ml/h (0.1ml/h step)
10ml:0.1ml/h-400.0ml/h (0.1ml/h step)
5ml: 200ml/h
Time ModeSOL. VOL:0.1-999.9ml (0.1ml step)
TIME:1-1999min (1min step)
Body Weight Mode:Volume:0.1-999.9ml(0.1ml step)
DRUG MASS:0.1-999.9mg 0.1mg step)
DOSE:0.01-99.99ug/kg/min(0.01ug/kg/min step)
WEIGHT:0.1-300kg(0.1kg the least step)
Total Volume Range0.1-1999.9ml (0.1 ml step)
Purge Rate50ml(60ml):1800.0ml/h,
20ml(30ml):800.0ml/h,
10ml:400.0ml/h, 5ml: 200ml/h
KVO Rate1ml/h
Occlusion pressureThree level setting LOW, MEDIUM or HIGH
AlarmsNear empty, Syringe empty, Volume complete (when limit volume is set), Occlusion, Syringe loose, Operation error, Low battery, device failures.
Three levels of alarm volume LOW, MEDIUM or HIGH
Bolus Rate5ml:10~200ml/h,10ml:10-300ml/h,20ml(30ml):10-600ml/h,
50ml(60ml):10-1200ml/h
Bolus VolumeMaximum of 25ml
InterfaceRS-232 Reserved port
Power sourceAC power supply: AC 100 to 240V( +/-10%),50/60Hz;
Built-in Lithium Battery:  Rechargeable, 11.1V, 2000mAh.
12 hours of continuous operation.
Accessories:AC power line, Operational manual
Protection ClassClass I, Type CF,IPX4
Dimension / Net weight230mm*150mm*125mm , 2.0kg
 

 
 Stackable Syringe Pump with Drug Library:  YSZS-1800Y
Yszs-1800y Medical Portable ICU Drug Library Electric Double Syringe Infusion Pump

 
Features:
  1. Compatible with syringes from (2/3ml), 5ml,10ml,20ml,30ml,50ml,60ml.
  2. Stackable to be the maximum 8 channels.
  1. High accuracy +/-2% after correct calibrated.
  2. Three work modes: Rate mode, Time mode and Weight mode.
  3. Bolus / Purge, KVO function.
  4. With drug libraries:17 categories of common drugs,1030 kinds of drug names in total.
  5. History recorded, real time displayed.
8.  12 hours continuous work after fully charged.
  
 
Technical Specifications
PARAMETERSPECIFICATION
Applicable syringes2/3ml, 5ml,10ml,20ml,30ml,50ml,60ml of any standard
Accuracy+/- 2% with correct calibration
Rate mode50ml(60ml):0.1ml/h-1800.0ml/h (0.1ml/h step)
20ml(30ml):0.1ml/h-800.0ml/h (0.1ml/h step)
10ml:0.1ml/h-400.0ml/h (0.1ml/h step)
5ml (2/3ml): 0.1~200ml/h (0.1ml/h step)
(Programmable 0.01ml/h~9999.9ml/h)
Time ModeSOL. VOL:0.1-999.9ml (0.1ml step)
TIME:1-1999min (1min step)
Body Weight Mode:Volume:0.1-999.9ml(0.1ml step)
DRUG MASS:0.1-999.9mg 0.1mg step)
DOSE:0.01-99.99ug/kg/min(0.01ug/kg/min step)
WEIGHT:0.1-300kg(0.1kg the least step)
Total Volume Range0.1-1999.9ml (0.1 ml step)
Purge Rate50ml(60ml):1800.0ml/h,
20ml(30ml):800.0ml/h,
10ml:400.0ml/h, 5ml (2/3ml): 200ml/h
Programmable and adjustable
KVO Rate1ml/h
Occlusion pressureThree level setting LOW, MEDIUM or HIGH
AlarmsNear empty, Syringe empty, Volume complete (when limit volume is set), Occlusion, Syringe loose, Operation error, Low battery, device failures.
Three levels of alarm volume LOW, MEDIUM or HIGH
Bolus Rate5ml: 10~200ml/h,10ml:10-300ml/h,20ml(30ml):10-600ml/h,
50ml(60ml):10-1200ml/h
Programmable and adjustable
Bolus VolumeMaximum of 25ml
InterfaceRS-232  (Reserved port)
Power sourceAC power supply: AC 100 to 240V( +/-10%),50/60Hz;
Built-in Lithium Battery: Rechargeable, 11.1V, 2000mAh.
12 hours of continuous operation
Accessories:AC power line, Operational manual
Protection ClassClass I, Type CF,IPX4
Dimension / Net weight230mm*150mm*125mm , 2.0kg
 

 

Send your message to this supplier

*From:
*To:
avatar Mr. Andy Guo
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Loading...

Product Groups

Contact Supplier

Mr. Andy Guo
Sales Manager