Medical Hospital Surgical Electrically Respirator Ventilator

Product Details
Customization: Available
out Looking: Mobile
Display: 10.4′′ LCD Display
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Terms of Payment
LC, T/T, Western Union, Money Gram
OEM/ODM Availability
Yes
  • Medical Hospital Surgical Electrically Respirator Ventilator
  • Medical Hospital Surgical Electrically Respirator Ventilator
  • Medical Hospital Surgical Electrically Respirator Ventilator
  • Medical Hospital Surgical Electrically Respirator Ventilator
  • Medical Hospital Surgical Electrically Respirator Ventilator
  • Medical Hospital Surgical Electrically Respirator Ventilator
Find Similar Products

Basic Info.

Model NO.
YSAV70A
Peep
0 ~ 1.0 Kpa
Inspiratory Plateau
0~1s
Gas Requirement
Oxygen with a Pressure Ranging From 280~600kpa
Imv Frequency
1~20 Bpm
Ambient Temperature
10 ~ 40oc
Transport Package
Wooden Case
Specification
CE certificate
Trademark
YSENMED
Origin
China
Production Capacity
2 000 Sets/Year

Product Description

Medical Surgical Electrically Respirator Ventilator 
Medical Hospital Surgical Electrically Respirator Ventilator

 
TECHNIQUES SPECIFICATIONS
Physical specifications
Display 10.4'' LCD Display
Mode: pneumatically powered and electrically controlled system
Trolley: Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions
Technical Specifications:
Gas requirement: Medical oxygen and nitrous oxide with a pressure ranging from 280~600kpa
safety valve <12.5 kPa
Respiratory Rate 1 ~ 99 bpm
Oxygen concentration output 21% ~ 100% adjustable
Maximum Minute ventilation ≥18L / min
modes of ventilation A/C, IPPV, SIPPV, IMV, SIMV, PEET. MANUAL, SIGH, SPONT
Ventilator compliance ≤30 Ml/kPa
PEEP: 0 ~ 1.0 kPa
Ptr: -10 ~ 10 hPa
IMV frequency: 1~20 bpm
I/E Ratio: 4:1~1:4, Has the inverse ratio ventilation
Tidal Volume Setting Range: 50~1500ML     Display Range: 0~2000ml ;   resolution ratio: 10ml
Inspiratory Plateau: 0~1s
Maximum Safety Pressure ≤ 6.0kPa
Sigh: one deep breath per 80 controlled respirations, the inspiration time is 1.5 times of the setting point
Pressure limit range: 1.0~ 6.0kPa
Airway pressure alarm: Audible and visual and with yellow and red color indicating Lower: 0.1 kPa ~ 6.0 kPa;   Upper: 0 ~ 5.0 kPa
±0.2 kPa
Ventilation Volume alarm: ≥ 18L/ MIN
Power Supply Alarm Ac/dc power supply are after failing to send out alarm immediately
Alarm Time: keep >120s
The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm, the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic respirator.
Operating conditions
Ambient temperature: 10 ~ 40oC
Relative humidity: no higher than 80 %
Atmospheric pressure: 860 hPa ~ 1060 hPa
Power requirement: 100-120 Vac, 50/60 Hz; 
Attention: the AC power supply used for the anesthesia machine must be well     grounded.
Attention: the anesthesia machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993, an oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical Electrical Equipment Part II: Special Requirements for Safety and Basic Performance of Anesthesia System.
Storage
Ambient temperature: -15oC ~ +50oC
Relative humidity: no higher than 95 %
Atmospheric pressure: 86 kPa ~ 106 kPa.
  It should be stored in a room without corrosive gas and well ventilated
Package
packaging box comply with the requirement of GB/T 15464
  Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportation
  Moisture protection and rain protection to ensure that product is protected from natural damage.
Safty & Alarm
Gas source pressure Immediate alarm; "high level alarm" indicator flickers raising an audible alarm.
Airway Pressure Alarm The airway pressure exceeds 15hpa. The maximum delay is no longer than 17s. The "high level alarm" indicator flickers raising an audible alarm.
Tidal Volume Alarm Lower than 50ml, The alarm will be raised after one breathing cycle.
Ventilation Volume Alarm Lower: 0~12L/Min;   Up: 18L/ Min
Battery Voltage Alarm It alrms when the battery voltage is lower than 10.5V.
Power On Self Test Self test before working, assure it's working normally.
STANDARD CONFIGURATIONS
QTY NAME
1 set Main unit
1 set Oxygen tube
2 set Silicone Mask
1 pc Power line
4 pcs Threaded pipe
2 pcs Standard Pipe
1 set Oxygen Reducer
1 set Humidifier
1 pc Battery
2 set flow sensor
2 pcs A leather bag ( Blue)
1 set Tools with the machine
1 set User Manual (English Version)



Related production:
YSAV50A Medical Surgical Electrically Respirator Ventilator 

Medical Hospital Surgical Electrically Respirator Ventilator
 
The YSAV50A ventilator is an electrically controlled pneumatic ventilator integrating such functions as time, volume cycling, pressure limit, etc. It is mainly intended for providing ventilation support to a critically ill patient during the life threatening phase and ensuring the going-through of the dangerous period by the patient and smooth treatment of primary diseases for recovery. Also it provides an alternation in case of irreversible lesions in respiratory muscles or irreversible damage to upper airway to maintain the respiratory function of the patient, and also provides ventilation assistance for the patient during the recovery from a disease or operation.
ALL MANIN UNIT HAS PASS THE CE
The automatic conversion for standby power while AC power outage, keep working not less than 1 hour
TECHNIQUES SPECIFICATIONS
Physical specifications
Display LED Display
Mode: pneumatically powered and electrically controlled system
Trolley: Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions
Technical Specifications:
Gas requirement: Medical oxygen with a pressure ranging from 280~600kpa
safety valve <12.5 kPa
Respiratory Rate 6~60 times/ min
Oxygen concentration output <50%
minute volume ≥18L
modes of ventilation A/C, IPPV, SIPPV, IMV, SIMV, PEET. MANUAL, SIGH
PEEP: 0.1 ~ 1.0 kPa
Ptr: -4 ~ 10 hPa
IMV frequency: 1~12 bpm
I/E Ratio: 1:1.5; 1:2.0; 1:2.5; 1:3.0
Tidal Volume Not less than 50~ 1200ml
Inspiratory Plateau: 0~1s
Maximum Safety Pressure ≤ 6.0kPa
Sigh: one deep breath per 80 controlled respirations, the inspiration time is 1.5 times of the setting point
Pressure limit range: 0 ~ 6.0 kPa
Airway pressure alarm: Audible and visual and with yellow and red color indicating Lower: 0.9 kPa ~ 5.4 kPa;   Upper: 0.5   kPa
±0.2 kPa
Ventilation Volume alarm: ≥ 18L/ MIN
Power Supply Alarm Ac/dc power supply are after failing to send out alarm immediately
Alarm Time: keep >120s
The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm, the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic respirator.
Operating conditions
Ambient temperature: 10 ~ 40oC
Relative humidity: no higher than 80 %
Atmospheric pressure: 860 hPa ~ 1060 hPa
Power requirement: 100-120 Vac, 50/60 Hz; 
Attention: the AC power supply used for the ICU ventilator must be well   grounded.
Storage
Ambient temperature: -15oC ~ +50oC
Relative humidity: no higher than 95 %
Atmospheric pressure: 86 kPa ~ 106 kPa.
  It should be stored in a room without corrosive gas and well ventilated
Package
packaging box comply with the requirement of GB/T 15464
  Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportation
  Moisture protection and rain protection to ensure that product is protected from natural damage.
Safty & Alarm
Gas source pressure Immediate alarm; "high level alarm" indicator flickers raising an audible alarm.
Airway Pressure Alarm The airway pressure exceeds 15hpa. The maximum delay is no longer than 17s. The "high level alarm" indicator flickers raising an audible alarm.
Tidal Volume Alarm Lower than 50ml, The alarm will be raised after one breathing cycle.
Ventilation Volume Alarm Lower: 0~12L/Min;   Up: 18L/ Min
Battery Voltage Alarm It alrms when the battery voltage is lower than 10.5V.
Power On Self Test Self test before working, assure it's working normally.
STANDARD CONFIGURATIONS
QTY NAME
1 set Main unit
1 set Oxygen tube
2 set Silicone Mask
1 pc Power line
2 pcs Threaded pipe
2 pcs Standard Pipe
1 set Oxygen Reducer
1 set Humidifier
1 pc Battery
1 set flow sensor
2 pcs A leather bag ( Blue)
1 set Tools with the machine
1 set User Manual (English Version)


We are a company aiming to make one stop shopping for our customers. We equiped hospital
operation room with many kind of items like operation table, orthopedic drill and saw, ECG,
defibrillator etc.
We listed some hospital operation room items basic items for your reference as below:
operation room anesthesia machine
ventilator
operating lamp
operation table
Pendant
medical drill and saw
ECG
patient monitor
Defibrillator
infusion pump
Electrocoagulation
oxygen generator
electric suction device
autoclave sterilizer
 
Medical Hospital Surgical Electrically Respirator Ventilator
Medical Hospital Surgical Electrically Respirator Ventilator
Medical Hospital Surgical Electrically Respirator Ventilator
Medical Hospital Surgical Electrically Respirator Ventilator

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More