Techniques Specifications Physical Spec: <12.5 Kpa
Ptr: -10 ~ 10 Hpa
Warranty Period: 12 Months
Customization:
Diamond Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
YSAV90A
Inspiratory Plateau
0~1s
Gas Requirement
Oxygen with a Pressure Ranging From 280~600kpa
I/E Ratio
4:1~1:4, Has The Inverse Ratio Ventilation
Pressure Limit Range
1.0~ 6.0kpa
Transport Package
Wooden Case
Specification
CE certificate
Trademark
YSENMED
Origin
China
Production Capacity
5, 000 Sets/Year

Product Description

Ysav90A Medical Ventilation Equipment Hospital Room Mobile Medical Respirator
Ysav90A Medical Ventilation Equipment Hospital Room Mobile Medical Respirator



 
TECHNIQUES SPECIFICATIONS
Physical specifications
Display 10.4'' LCD Display
Mode: pneumatically powered and electrically controlled system
Trolley: Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions
Technical Specifications:
Gas requirement: Medical oxygen and nitrous oxide with a pressure ranging from 280~600kpa
safety valve <12.5 kPa
Respiratory Rate 1 ~ 99 bpm
gas concentration output 21% ~ 100% adjustable
Maximum Minute ventilation ≥18L / min
modes of ventilation A/C, SIPPV,IPPV,SIMV,PSIMV,CPAP,PCV,PEEP,SIGN,SPONT, MANUAL
Ventilator compliance ≤30 Ml/kPa
PEEP: 0 ~ 1.0 kPa
Ptr: -10 ~ 10 hPa
IMV frequency: 1~20 bpm
I/E Ratio: 4:1~1:4, Has the inverse ratio ventilation
Tidal Volume Setting Range: 50~1500ML     Display Range: 0~2000ml ;   resolution ratio: 10ml
Inspiratory Plateau: 0~1s
Maximum Safety Pressure ≤ 6.0kPa
Sigh: one deep breath per 80 controlled respirations, the inspiration time is 1.5 times of the setting point
Pressure limit range: 1.0~ 6.0kPa
Airway pressure alarm: Audible and visual and with yellow and red color indicating Lower: 0.1 kPa ~ 6.0 kPa;   Upper: 0 ~ 5.0 kPa
±0.2 kPa
Ventilation Volume alarm: ≥ 18L/ MIN
Power Supply Alarm Ac/dc power supply are after failing to send out alarm immediately
Alarm Time: keep >120s
The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm, the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic respirator.
Operating conditions
Ambient temperature: 10 ~ 40oC
Relative humidity: no higher than 80 %
Atmospheric pressure: 860 hPa ~ 1060 hPa
Power requirement: 100-120 Vac, 50/60 Hz; 
Attention: the AC power supply used for the anesthesia machine must be well     grounded.
Attention: the anesthesia machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993, an oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical Electrical Equipment Part II: Special Requirements for Safety and Basic Performance of Anesthesia System.
Storage
Ambient temperature: -15oC ~ +50oC
Relative humidity: no higher than 95 %
Atmospheric pressure: 86 kPa ~ 106 kPa.
  It should be stored in a room without corrosive gas and well ventilated
Package
packaging box comply with the requirement of GB/T 15464
  Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportation
  Moisture protection and rain protection to ensure that product is protected from natural damage.
Safty & Alarm
Gas source pressure Immediate alarm; "high level alarm" indicator flickers raising an audible alarm.
Airway Pressure Alarm The airway pressure exceeds 15hpa. The maximum delay is no longer than 17s. The "high level alarm" indicator flickers raising an audible alarm.
Tidal Volume Alarm Lower than 50ml, The alarm will be raised after one breathing cycle.
Ventilation Volume Alarm Lower: 0~12L/Min;   Up: 18L/ Min
Battery Voltage Alarm It alrms when the battery voltage is lower than 10.5V.
Power On Self Test Self test before working, assure it's working normally.
STANDARD CONFIGURATIONS
QTY NAME
1 set Main unit
4 pcs Adult threaded pipe (Silica)
1 set Child threaded pipe (single use)
1 pc Oxygen Tube
1pc Y-Pipe
2pcs Mask (Silicom)
2pcs Leather Bag
2pcs Fuse
1pc Power Line
1pc Oxygen pressure reducer
4 pcs Hoop
1pc Battery
1pc Tools Attachment
1 set humidifier
1 set English Version User Manual
 

We are a company aiming to make one stop shopping for our customers. We equiped hospital
operation room with many kind of items like operation table, orthopedic drill and saw, ECG,
defibrillator etc.
We listed some hospital operation room items basic items for your reference as below:
operation room anesthesia machine
ventilator
operating lamp
operation table
Pendant
medical drill and saw
ECG
patient monitor
Defibrillator
infusion pump
Electrocoagulation
oxygen generator
electric suction device
autoclave sterilizer
 


Ysav90A Medical Ventilation Equipment Hospital Room Mobile Medical Respirator
Ysav90A Medical Ventilation Equipment Hospital Room Mobile Medical Respirator

Ysav90A Medical Ventilation Equipment Hospital Room Mobile Medical Respirator

Ysav90A Medical Ventilation Equipment Hospital Room Mobile Medical Respirator


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now