Gold Member Since 2010
Audited Supplier
Guangzhou Yueshen Medical Equipment Co., Ltd.

Anesthesia Machine, Anesthesia Equipment, Anesthesia manufacturer / supplier in China, offering YSAV603A Multifunctional LCD Display Anesthesia, Operating Room Medical Ventilator Ambulances Medical Ventilator Price, Ysvet10901L Hot Sale Pet Clinic Grooming Hair Dryer Pet Hair Dryer and so on.

(/ )

YSAV603A Multifunctional LCD Display Anesthesia

FOB Price: Get Latest Price
Min. Order: 1 Set
Port: Guangzhou, China
Production Capacity: 5, 000 Sets/Year
Payment Terms: L/C, T/T, Western Union, Money Gram

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: YSAV603A
  • Medical Devices Ad. Approval No.: Gsyjxzz2014-3541631
  • with Ventilator: Yes
  • Scope of Application: Adult, Child
  • Flow Meter: O2: 0.1~1.0L/Min 1.1~10L/Min;
  • Display Mode: 5.7" LCD Screen Display
  • Trademark: YSENMED
  • Specification: CE certificate
  • HS Code: 9018909000
  • Medical Device Regulatory Type: Type 3
  • out Looking: Mobile
  • Certificate: Ce, ISO
  • Gas Source: O2: 0.27~0.55MPa N2o: 0.27~0.55MPa
  • Flow Rate of Rapid Oxygen Supply: 25~75L/Min
  • Brand: Ysenmed
  • Transport Package: Wooden Case
  • Origin: China
Product Description
YSAV603A Multifunctional LCD Display Anesthesia

Anesthesia Machine, with its ergonomic design, integrates a concise and smooth structure and high mobility. 
The microcomputer-controlled Ventilator adopts exported sensors and other components. 
Its scientific and proper design as well as rigorous production process are what demonstrate the inner quality of Yueshen products: mechanical ventilation is made secure and visible by the folded respiratory bellows, and the security of air supply is guaranteed by pneumatic transmission and measurement system. 
With multiple modern technologies applied, the Anesthesia Machine is both outstanding in performance and versatile in functions.
Main bodyHigh-strength engineering plastic rack, light, beautiful and corrosion resistant
Scope of applicationadult, child
Gas sourceO2: 0.27-0.55MPa    N2O: 0.27-0.55MPa
Flow meterO2: 0.1-1.0L/min   1.1-10L/min
N20: 0.1-1.0L/min   1.1-10L/min
O2, N2O linkage and N2O Stopper
When using nitrous oxide, oxygen concentration>25%;
When the oxygen pressure<0.2Kpa, the flow of nitrous oxide would be cut off.
Flow rate of rapid oxygen supply25-75L/min
Low oxygen pressure alarm
 
There will be sound alarm when the oxygen
pressure < 0.2MPa
Vaporizerit has the function of automatic compensation based on
pressure, temperature, and flow rate. The regulation
range of evaporator concentration is 0-5 vol%. Among
Halothane, Enflurane, Isoflurane and Sevoflurane, one
can be chosen for application as required by the
customer. And vaporizers that are imported with original
packaging are also available.
Respiratory circuit
 
working mode: all-close, semi-close, semi-open
releasing pressure: 0.5-7 kPa
Respiratory Bellows
 
bellows for adults, bellows for children
tidal volume range:0-1,500 ml
Ventilator
Display modeHigh-definition TFT color LCD screen display
Ventilation  mode
 
IPPV, SIPPV, SIMV, PEEP, MANUAL, 
SIGH, (IMV, VCV, PCV)
Ventilation parametersTidal volume50-1500 ml (20-1500 ml)
Rate1-99 bpm
SIMV rate2-20 bpm
I:E2:1-1:8 (4:1-1:8)
Inspiratory trigger pressure-1.0-2.0Kpa
PEEP
Pressure Range
0-2.0Kpa
1.0-6.0Kpa
SIGH1.5 times the inspiratory time (70-150 adjustable)
Inspiratory platform0-50%
Parameters for ventilation monitoring tidal volume, ventilation volume, 
IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, 
average pressure, pressure - time waveform, flow rate - time waveform, PEEP, 
inspiratory trigger pressure, Inspiratory platform (autonomous inspiratory rate, 
lung compliance, airway resistance,flow-volume oop,pressure-volume loop)
Monitoring of oxygen concentration21%-100%
Security Alarm System
Oxygen Concentration alarmupper limit setting range  21%-100%
low limit setting range   10%-80%
Airway pressure alarm  upper limit setting range  0.3-6.0 kPa
low limit setting range   0.2-5.0 kPa
Per-minute ventilation volume alarm    upper limit setting range 3.0-30L/min
low limit setting range   1.0-10L/min
Sustained high-pressure alarmit will give alarm when stress have consistently been higher than 2.5 kPa
Suffocation alarmit will give sound and light alarm if there
is no tidal volume input for 15 seconds
Power alarm
PowerAC 220V±10%     50Hz±1Hz (UPS, Storage battery)
(Mechanical Arms)  (End-expiratory CO2 monitoring)
Items within brackets are optional.
Product Groups
Send your message to this supplier
Avatar
Miss Cici Huang
*From:
To: Miss Cici Huang
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

Find Similar Products By Category